Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Shembekar, Suraj N.a; | Zodpe, D.B.a | Padole, P.M.a
Affiliations: [a] Department of Mechanical Engineering, Visvesvaraya National Institute of Technology, Nagpur, Maharashtra, India
Correspondence: [*] Corresponding author: Suraj N. Shembekar, Department of Mechanical Engineering, Visvesvaraya National Institute of Technology, Nagpur 440010, Maharashtra, India. E-mail: aerosuraj1310@gmail.com
Abstract: BACKGROUND:Arteriovenous fistula (AVF) is the preferred route of vascular access in hemodialysis. The primary reason of fistula failure is intimal hyperplasia (IH), which leads to stenosis. Wall shear stress (WSS) and disturbed flow are the critical parameters in the formation of IH. OBJECTIVE:The primary goal of this study is to explore the influence of anastomosis angle on WSS and venous outflow rate, as well as to find the ideal angle of anastomosis for AVF to standardize surgical technique. METHODS:Three-dimensional idealized geometries of end-to-side type AVF for the five various angles of anastomosis are considered in this study. The WSS, blood flow rate at the venous outlet for non-Newtonian, pulsatile blood flow are calculated using a numerical simulation technique. RESULTS:The WSS is higher at 75° compared to other angles and least at 45° for pulsating arterial inflows. The WSS is moderate at 30°, 60° and 90°. On the arterial bed and outer wall of the vein, immediately after the anastomosis, the recirculation zone is observed. At an angle of 45° and 90° anastomosis, the outflow rate is greater at distal venous end. CONCLUSIONS:If one believes that high wall shear stress causes IH within the AVF, the results suggest that the AVF should be formed at a 45° angle to avoid IH. However, if one believes that low wall shear stress causes IH within the AVF, the results suggest that AVF should be formed at either 30° or 75° to avoid IH. The findings spotlight the importance of anastomosis angle in determining AVF hemodynamics.
Keywords: Arteriovenous fistula, anastomosis angle, hemodialysis, vascular access, wall shear stress
DOI: 10.3233/BME-211389
Journal: Bio-Medical Materials and Engineering, vol. 33, no. 5, pp. 423-436, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl