Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Xue, Yanga; | Wang, Xiong-Feia; | Zhao, Fu-Longa | Han, Da-Chenga | Long, An-Huaa | Wang, Jinb; | Zhang, Ya-Kuia; | Wang, Xue-Feia;
Affiliations: [a] Department of Trauma and Orthopaedics, Beijing LuHe Hospital Affiliated to Capital Medical University, Beijing, China | [b] School of Chemistry and Chemical Engineering, Nantong University, Nantong, China
Correspondence: [*] Corresponding authors: Jin Wang, School of Chemistry and Chemical Engineering, Nantong University, Nantong 226019, China. E-mail: wangjin110@ntu.edu.cn. Ya-Kui Zhang, Department of Trauma and Orthopaedics, Beijing LuHe Hospital Affiliated to Capital Medical University, Beijing 101100, China. E-mail: zhangyakui@vip.sina.com. Xue-Fei Wang, Department of Trauma and Orthopaedics, Beijing LuHe Hospital Affiliated to Capital Medical University, Beijing 101100, China. E-mail: xuefeiw@vip.sina.com
Note: [†] These authors contributed equally to this study.
Abstract: BACKGROUND:Femoral neck fracture is an unsolved challenge in orthopedics. The complication rate in particular is high. There remains a lack of consensus on the optimal choice of internal fixation for unstable femoral neck fracture. OBJECTIVE:The study aimed to develop a new headless compression supporting screw (HCSS) for the treatment of unstable foemoral neck fracture. METHODS:We designed a new HCSS and used a femoral neck fracture (Pauwels III fracture) model (left, fourth-generation composite, Sawbones) and three-dimensional finite element analysis to compare the biomechanical performance of HCSSs with that of cannulated compression screws (CCSs) for treatment of unstable femoral neck fracture. RESULTS:Maximum displacement, peak von Mises stress, peak strain, and rotation for the HCSS were smaller than those for the CCS. The stress was more widely distributed for the HCSS, whereas the stress was concentrated for the CCS. CONCLUSIONS:The HCSS resulted in better biomechanical stability than that from the CCS. For Pauwels III fractures the HCSS exhibits better resistance to shear forces and better support, providing a new clinical treatment.
Keywords: Femoral neck fracture, Pauwels III, fracture finite element analysis, cannulated compression screw, headless compression support screw
DOI: 10.3233/BME-211313
Journal: Bio-Medical Materials and Engineering, vol. 33, no. 4, pp. 279-292, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl