Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Miyata, Ryujia | Matsumoto, Shujia; b; | Miura, Seijia | Kawamura, Kentaroa | Uema, Tomohiroc | Miyara, Kodaic | Niibo, Ayanad | Hoei, Takashie | Ogura, Tadashie | Shimodozono, Megumia
Affiliations: [a] Department of Rehabilitation and Physical Medicine, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan | [b] Department of Rehabilitation and Physical Medicine, Graduate School of Medicine, Nippon Medical School, Tokyo, Japan | [c] Department of Rehabilitation, Kirishima Rehabilitation Center of Kagoshima University Hospital, Kagoshima, Japan | [d] Department of Rehabilitation, Tarumizu Municipal Medical Center, Tarumizu Central Hospital, Kagoshima, Japan | [e] Department of Rehabilitation, Koshinkai Ogura Hospital, Kagoshima, Japan
Correspondence: [*] Corresponding author: Shuji Matsumoto, Department of Rehabilitation and Physical Medicine, Graduate School of Medicine, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo 113-8603, Japan. Tel.: +81 3 3822 2131; Fax: +81 476 99 1917; E-mail: shushusa71@yahoo.co.jp
Abstract: BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patients. To assess intra-rater reliability, rater A tested subjects on three separate occasions (Days 1, 2, and 3). To assess inter-rater reliability, raters A and B independently tested participants on the same occasion (Day 3). RESULTS:There was no significant systematic bias between test occasions or raters. Intraclass correlation coefficient values were 0.93–0.97 for intra-rater reliability at both the comfortable speed and maximum speed, and 0.97–0.98 (comfortable speed) and 0.97–0.99 (maximum speed) for inter-rater reliability. The standard error was 1.25–1.49 (comfortable speed) and 1.62–1.77 (maximum speed) for intra-rater investigation, and 1.04–1.32 (comfortable speed) and 0.91–1.26 (maximum speed) for inter-rater investigation. At the 90% confidence level, the minimum detectable change ranged from 2.9–4.1%, and the error of an individual’s score at a given time point ranged from ±2.1–2.9%. CONCLUSIONS:Based on this excellent reliability of the PGR in post-stroke patients, it can be recommended as a simple test of gait analysis in this population.
Keywords: Acceleration, gait analysis, portable gait rhythmogram, reliability, stroke
DOI: 10.3233/BME-206007
Journal: Bio-Medical Materials and Engineering, vol. 31, no. 6, pp. 329-338, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl