Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ramu, M.a; | Ananthasubramanian, M.b | Kumaresan, T.c; | Gandhinathan, R.c | Jothi, Sathiskumard; e; f
Affiliations: [a] Department of Mechanical Engineering, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, India | [b] Department of Biotechnology, PSG College of Technology, Coimbatore, India | [c] Department of Production Engineering, PSG College of Technology, Coimbatore, India | [d] Big Data Science & Technology Limited, Research and Technology Development Division, London, UK | [e] Material Intelligence & Big Data Science (MI-BDS) Research Group, Swansea University, Bay Campus, Swansea, UK | [f] Advance Materials, Mechanics & Manufacturing (AM3) Group, Material Research Centre, College of Engineering, Swansea University, Bay Campus, Swansea, UK
Correspondence: [*] Corresponding authors. E-mails: m_ramu@cb.amrita.edu; kumaresanthavasi@gmail.com
Abstract: Numerous biomaterials are used to fabricate bone scaffolds to repair the bones subjected to trauma. The scaffolds are fabricated with interconnected pores with 40–70% porosity to facilitate the entry of the cells that ensures rapid bone formation. In addition, the interconnected pores also serve as a channel for the exchange of nutrients and waste materials. Rapid prototyping techniques use the CAD model of the scaffold to be fabricated which facilitates fabrication of components with complex architecture easily. This research deals with the design, fabrication and analysis of porous scaffold models with different configurations. Apart from the conventional pore geometry like cubical, spherical shaped pores, their shifted arrangements were also considered for this study. The minimum pore size used for the study is 400 μm and the porosity ranges from 40–70%. Based on the results of finite element analysis, the best scaffold configuration is identified and was fabricated with different build orientation using Selective Laser Sintering (SLS) process with different mix of Polyamide and Hydroxyapatite. The fabricated test specimens were evaluated based on mechanical tests for its strength and in vitro studies with human osteosarcoma cell line for cell growth studies. The mechanical tests witnesses good physical properties than the earlier reported research. The suitability of the porous scaffolds for bone repair is also ensured using finite element analysis of a human femur bone under various physical activities.
Keywords: Femur bone, Polyamide (PA), Hydroxyapatite (HA), Selective Laser Sintering (SLS), finite element analysis (FEA), porous scaffold
DOI: 10.3233/BME-181020
Journal: Bio-Medical Materials and Engineering, vol. 29, no. 6, pp. 739-755, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl