Authors: Greiner, Axel | Bongartz, Anne | Woiczinski, Matthias | Befrui, Nima | Pieske, Oliver | Suero, Eduardo M. | Bruder, Jan | Kammerlander, Christian | Böcker, Wolfgang | Becker, Christopher A.
Article Type:
Research Article
Abstract:
BACKGROUND: Vertebroplasty and kyphoplasty are now well-established methods for treating compression fractures of vertebral bodies (AO type A) as well as vertebral body metastases [1 , 2 , 3 ]. However, polymethylmethacrylate (PMMA) augmented vertebrae show fractures of subsequent vertebral bodies due to the increased stability of the augmented vertebral body [4 ]. Resorbable cements are currently only used experimentally. Many commercially available resorbable calcium phosphate cements do not exhibit sufficient biomechanical stability to treat vertebral body fractures [5 ]. Resomer C212 © (Evonik Industries AG, Essen, Germany) is a slow resorbable poly-ε -caprolactone that has
…low melting temperatures and good biomechanical properties. OBJECTIVE: This is a feasibility study on how the poly-ε -caprolactone Resomer C212 © can be used for kypho- or vertebroplasty, what temperatures are used in the argumentation and how differences in load capacity are measurable compared to conventional PMMA cement. METHODS: 23 Sawbones © blocks (7.5 Open Cell Foam, SKU: 1522-09, laminated on both sides, 4 × 4 × 2.9 cm, Sawbones, Vashon Island, USA) were divided into three groups: 7 without augmentation, 8 augmented with PMMA cement Traumacem V+ © (DePuy Synthes, West Chester, USA) and 8 augmented with Resomer C212 © . Temperature measurements were made in a 37 ∘ C water bath centrally in the block and on the top and bottom plates. This was followed by a maximum load of up to 2000 N using a universal testing machine (Instron E 10000, Instron Industrial Products, Grove City, USA). RESULTS: In the Resomer C212 © test group, the maximum average increase in temperature was 4.15 ± 4.72 ∘ C central, 0.3 ± 0.31 ∘ C at the top and 0.78 ± 1.27 ∘ C at the base. In the cement test group, the average increase in temperature was 9.80 ± 10.65 ∘ C centrally in the test block, 1.50 ± 0.73 ∘ C at the top plate and 1.42 ± 0.66 ∘ C and the base plate. In the axial compression test, the 7 non-kyphoplasted test blocks showed a first loading peak on average at 275.23 ± 80.98 N, a rigidity of 238.47 ± 71.01 N/mm 2 . In the Traumacem V+ © group, the mean peak load was 313.72 ± 46.26 N and rigidity was 353.45 ± 77.23 N/mm 2 . The Resomer C212 © group achieved a peak load of 311.74 ± 52.05 N and a stiffness of 311.30 ± 126.63 N/mm 2 . A compression to 50% could not be seen in any test block under the load of 2000 N. At 2000 N, Traumacem V+ © ’s average height reduction was 9.26 ± 2.16 mm and Resomer C212 © was 10.93 ± 0.81 mm. CONCLUSIONS: It has been shown that the application of Resomer C212 © in kyphoplasty or vertebroplasty is well feasible. Thermal analysis showed significantly lower temperatures and shorter temperature application in the Resomer C212 © group. In the biomechanical load up to 2000 N no significant differences could be observed between the individual groups.
Show more
Keywords: Kyphoplasty, resomer, resorbable, vertebral fracture, biomechanics
DOI: 10.3233/THC-202159
Citation: Technology and Health Care,
vol. 29, no. 2, pp. 343-350, 2021
Price: EUR 27.50