Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cuypers, M.H.M. | Thijssen, J.M.; *
Affiliations: Biophysics Laboratory of the Department of Ophthalmology, University Hospital, P.O. BOX 9101, 6500 HB Nijmegen Netherlands
Correspondence: [*] Corresponding author. Tel +31.80.614448, fax +31.80.540522.
Abstract: Ensemble averaging is generally used for the estimation of Evoked Potentials. This paper deals with the assessment of correction procedures for the time variability of the ensemble components, this time variability reduces the improvement of the signal-to-noise ratio (SNR) by averaging. Evoked potentials were estimated by ensemble averaging, synchronized to a periodic stimulus. It is assumed that VEP-instability is partly caused by time-variability of the evoked potentials. Two time-variate models were used, from which procedures were derived to correct the single VEP-responses prior to ensemble averaging. The models are: (1) variation in response delay (jitter), (2) variable compression/expansion of the time scale of the response (wow). The Spectral Phase Difference method was applied to estimate both the delay time jitter and the wow factor of single responses with respect to a template (conventional ensemble average). The effects of the devised correction on the average VEP waveform and on the SNR of the ensemble were investigated by using data from realistic simulations and from experiments (n = 23) with a number of healthy human volunteers (n = 17). Jitter- and wow-corrections were effective on simulations with time variability due to delay time jitter and time scale distortion (wow), respectively. Both wow- and jitter correction of the single responses improved the SNR of the VEP measurements significantly and to the same amount. A combined wow-jitter approach resulted in significantly better results than the exclusive application of jitter- or wow correction.
Keywords: Evoked potential, Visual, Delay time jitter, Wow, Time scale distortion, Spectral processing, Averaging
DOI: 10.3233/THC-1995-3106
Journal: Technology and Health Care, vol. 3, no. 1, pp. 33-42, 1995
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl