Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cho, Ki-Huna | Lee, Dong-Geonb | Song, Won-Kyungc | Lee, Gyuchangd; *
Affiliations: [a] Department of Physical Therapy, Korea National University of Transportation, Jeungpyeong, Korea | [b] Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Korea | [c] Department of Rehabilitative and Assistive Technology, National Rehabilitation Research Institute, National Rehabilitation Center, Seoul, Korea | [d] Outreach Physical, Occupational, and Speech Therapy, New York, NY, USA
Correspondence: [*] Corresponding author: Gyu-Chang Lee, Outreach Physical, Occupational, and Speech Therapy, 1110 2nd Ave # 302, New York, NY 10022 USA. E-mail: leegc76@hanmail.net(cc:mamiya34@gmail.com).
Abstract: BACKGROUND: After stroke, gait training is a key component of rehabilitation, and most individuals use a variety of walking aids depending on their physical condition and environment. OBJECTIVE: This study aimed to investigate the potential effect of a one-arm motorized gait device for gait assist of chronic hemiplegic stroke survivors through comparison with traditional gait devices (parallel bar and hemi-walker). METHODS: This study was conducted on 14 chronic hemiplegic stroke survivors. The participants were asked to walk under three conditions using different gait devices, and their gait parameters during walking were collected and analyzed. The first condition involved walking on parallel bars; second condition, walking using hemi-walkers; and third condition, walking using one-arm motorized gait devices. With the use of a gait analysis system, the spatio-temporal gait parameters in each condition were collected, such as gait velocity, cadence, step length, stride length, single support time, and double support time. RESULTS: In the results by repeated-measures ANOVA or the Friedman test, a significant difference was found in the gait parameters among all three conditions (p< 0.05). The post-hoc test showed a significant change in the spatio-temporal gait parameters (especially, velocity, cadence and affected side single and double support time) when one-arm motorized gait device were used compared with parallel bars and hemi-walkers (p< 0.05). CONCLUSION: The results of this study suggest that one-arm motorized gait devices developed for hemiplegic stroke survivors may be more effective potentially than parallel bars and hemi-walkers in gait assistance of chronic hemiplegic stroke survivors.
Keywords: Chronic hemiplegic stroke, gait characteristics, one-arm motorized gait device, parallel bars, hemi-walker
DOI: 10.3233/THC-230197
Journal: Technology and Health Care, vol. 32, no. 1, pp. 335-342, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl