Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Alqahtani, Nasser M.a | Alqahtani, Ali Fahedb | Zarbah, Mohammad A.a | Alqahtani, Saeed M.a | Shukla, Anuj Kishorc; * | Kulkarni, Manisha Mangeshd
Affiliations: [a] Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia | [b] Department of Periodontics and Community Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia | [c] Department of Dentistry, Government Medical College, Ratlam, India | [d] Department of Prosthodontics, YCMM RDF’s Dental College, Ahmednagar, India
Correspondence: [*] Corresponding author: Anuj Kishor Shukla, Department of Dentistry, Government Medical College, Ratlam, India. E-mail: kishoranuj018@gmail.com.
Abstract: BACKGROUND: The prime concern of an implant-supported prosthesis (ISP) is to maintain an optimal proximal contact tightness, which further maintains arch integrity, improves masticatory effectiveness, and minimizes peri-implantitis. OBJECTIVE: To investigate the loss of proximal contact tightness between single tooth implant-supported prosthesis and the adjacent natural teeth. METHODS: Forty patients treated by a single mandibular first molar ISP, aged between 18–50 years were selected. All were randomly allocated in Group I and Group II. Group I, 20 subjects who have received ISP without an insertion of Essix retainer, and Group II patients received an insertion with Essix retainer. The groups were subdivided into Subgroup A, B, and Subgroup C, D, in which A and C are control groups. To measure the tightness at proximal contact points, a digital force analyzer was used. Proximal contact tightness (PCT) was measured immediately after the placement of the prosthesis, 3 months, 6 months, and 1-year follow-up respectively, and the PCT values at end of 1 year were statistically evaluated. Statistical analysis was done, mean and standard deviation was calculated by independent sample t-test wit p< 0.05 as a statistically significant value. RESULTS: In Group I, towards the end of 1 year, 2.09 N (65.5%) and 1.50 N (53.1%) loss of PCT were found on mesial and distal contact areas respectively. In Group II, loss of PCT at mesial contact area was 0.87 N (28.9%) and at distal contact area was 1.77 N (53.3%), which is significantly less compared with the non-usage of Essix retainer (p< 0.05). CONCLUSION: The usage of Essix retainer, PCT increases especially on the mesial contact area. The frequency of contact loss was decreased. Thus, to minimize the loss of proximal contact the usage of Essix retainer is recommended.
Keywords: Proximal contact loss, implant supported prosthesis (ISP), contact area, digital force analyzer
DOI: 10.3233/THC-220028
Journal: Technology and Health Care, vol. 30, no. 6, pp. 1435-1442, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl