Article type: Research Article
Authors: Jiang, Xia | Li, Li | Xue, Hong-Yuan*
Affiliations: Department of Ultrasound, Hebei General Hospital, Shijiazhuang, Hebei, China
Correspondence: [*] Corresponding author: Hong-Yuan Xue, Department of Ultrasound, Hebei General Hospital, No. 348 Heping West Road, Xinhua District, Shijiazhuang, Hebei 050051, China. Tel.: +86 311 8598 8904; Fax: +86 311 8598 8904; E-mail: xueyuanhong55dd@163.com.
Abstract: BACKGROUND: In the past ten years, liver biopsies have been used as a method to accurately diagnose the stage of fibrosis. OBJECTIVE: This study aimed to evaluate whether body position and exercise affect the measurement of liver Young’s modulus of healthy volunteers by real-time shear wave elastography (RT-SWE). Methods: RT-SWE was used to measure liver Young’s modulus in the supine and left lateral positions of 70 healthy volunteers at rest and measure the liver Young’s modulus in the lying position before exercise, and at zero, five, and ten minutes of rest after exercise. RESULTS: The liver Young’s modulus in the left lateral position was significantly higher than in the supine position (P< 0.05), and the measured value in the supine position was more stable than the left lateral position. The liver Young’s modulus measured at zero minutes after exercise was significantly higher than that measured before exercise (P< 0.05). The liver Young’s modulus measured at five minutes after exercise was significantly higher than that measured at zero minutes after exercise (P<0.05) and was not statistically different from the measured value before exercise (P> 0.05). The liver Young’s modulus measured at ten minutes after exercise was significantly higher from that measured at zero minutes after exercise (P< 0.05) and was not statistically different from the measured value at five minutes after exercise (P> 0.05). CONCLUSION: Body position and exercise have a significant impact on the measurement of liver Young’s modulus. It is recommended that the examinees take a supine position during the measurement, and measurement should be conducted at least ten minutes after exercise.
Keywords: Real-time shear wave elastography, position, exercise, liver Young’s modulus, liver stiffness
DOI: 10.3233/THC-213218
Journal: Technology and Health Care, vol. 30, no. 2, pp. 445-454, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl