Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chaturvedi, Saurabh* | Addas, Mohamed Khaled | Alqahtani, Nasser M. | Al Ahmari, Nasser M. | Alfarsi, Mohammed A.
Affiliations: Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
Correspondence: [*] Corresponding author: Saurabh Chaturvedi, Department of Prosthodontics, College of Dentistry, King Khalid University, Saudi Arabia. Tel.: +966 580697248; E-mail: survedi@kku.edu.sa.
Abstract: BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS:A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes – bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p< 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p> 0.05) but statistically significant differences (p< 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 ± 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 ± 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
Keywords: Digital dentures, T-Scan, occlusal forces, subtractive technique, additive technique milling, CAD-CAM
DOI: 10.3233/THC-202766
Journal: Technology and Health Care, vol. 29, no. 4, pp. 797-811, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl