Article type: Research Article
Authors: Wang, Fengsuia; b; c; * | Wang, Qishenga; b; c | Liu, Furonga; b; c | Chen, Jinganga; b; c | Fu, Linjuna; b; c | Zhao, Faa; b; c
Affiliations: [a] School of Electrical Engineering, Anhui Polytechnic University, Wuhu, Anhui, China | [b] Key Laboratory of Detection Technology and Energy Saving Devices, Wuhu, Anhui, China | [c] Key Laboratory of Advanced Perception and Intelligent Control of High-end Equipment, Ministry of Education, Wuhu, Anhui, China
Correspondence: [*] Corresponding author: Fengsui Wang, School of Electrical Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, China. E-mail: fswang@ahpu.edu.cn.
Abstract: BACKGROUND: Traditional least mean square algorithm (LMS) tends to converge faster and thus the larger the steady-state error of the algorithm. OBJECTIVE: In order to solve this issue, an improved adaptive normalized least mean square (NLMS) ECG signal denoising algorithm is proposed through utilizing the NLMS and the least mean square algorithm with added momentum term (MLMS). METHODS: The algorithm firstly performs LMS adaptive filtering on the original ECG signal. Then, the algorithm uses the relative error of the prior error signal and the posterior error signal before and after filtering to adaptively determine the iteration step factor. Finally, the expected error is set to determine whether the denoising meets the expected requirements. This method is applied to the MIT-BIH ECG database established by the Massachusetts Institute of Technology. RESULTS: Experimental results have shown that the proposed algorithm can achieve good denoising for the target signal, and the average signal to noise ratio (SNR) of the proposed method is 17.6016, the RMSE is only 0.0334, and the average smoothness index R is only 0.0325. CONCLUSION: The proposed algorithm effectively removes the original ECG signal noise, and improves the smoothness of the signal the denoising efficiency.
Keywords: ECG signal, adaptive filter, normalized minimum mean square, signal to noise ratio
DOI: 10.3233/THC-202659
Journal: Technology and Health Care, vol. 29, no. 2, pp. 305-316, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl