Issue title: Advances in Biomedical Engineering: Research that bridges the gap between Engineering and Medicine
Guest editors: Julius Griškevičius.
Article type: Other
Authors: Ostaszewski, Michal | Pauk, Jolanta*
Affiliations: Department of Automatic Control And Robotics, Faculty of Mechanical Engineering, Bialystok University of Technology, Bialystok, Poland
Correspondence: [*] Corresponding author: Jolanta Pauk, Faculty of Mechanical Engineering, Department of Automatic Control And Robotics, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland. Tel.: +48 510 034 086; Fax: +48 85 7469210; E-mail: j.pauk@pb.edu.pl.
Abstract: BACKGROUND:Gait analysis is a useful tool medical staff use to support clinical decision making. There is still an urgent need to develop low-cost and unobtrusive mobile health monitoring systems. OBJECTIVE: The goal of this study was twofold. Firstly, a wearable sensor system composed of plantar pressure insoles and wearable sensors for joint angle measurement was developed. Secondly, the accuracy of the system in the measurement of ground reaction forces and joint moments was examined. METHODS:The measurements included joint angles and plantar pressure distribution. To validate the wearable sensor system and examine the effectiveness of the proposed method for gait analysis, an experimental study on ten volunteer subjects was conducted. The accuracy of measurement of ground reaction forces and joint moments was validated against the results obtained from a reference motion capture system. RESULTS:Ground reaction forces and joint moments measured by the wearable sensor system showed a root mean square error of 1% for min. GRF and 27.3% for knee extension moment. The correlation coefficient was over 0.9, in comparison with the stationary motion capture system. CONCLUSIONS:The study suggests that the wearable sensor system could be recommended both for research and clinical applications outside a typical gait laboratory.
Keywords: Pressure sensors, ground reaction forces, joint moments, gait, wearable system
DOI: 10.3233/THC-182507
Journal: Technology and Health Care, vol. 26, no. S2, pp. 605-612, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl