Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Gao, Yongxianga | Zhao, Zhib | Chen, Yimina | Mahara, Gehendraa | Huang, Jialinga | Lin, Zhuochena | Zhang, Jinxina; *
Affiliations: [a] Department of Medical Statistics and Epidemiology, School of Public Health, Sun Yat-sen University, Guangzhou, Guangdong, China | [b] Department of Biostatistics, University of Oslo, Oslo, Norway
Correspondence: [*] Corresponding author: Jinxin Zhang, Department of Medical Statistics and Epidemiology, School of Public Health, Sun Yat-sen University, No. 74 Zhongshan Rd. 2, Guangzhou, Guangdong, China. Tel.: +86 20 87332453; E-mail: zhjinx@mail.sysu.edu.cn.
Abstract: BACKGROUND: An electroencephalogram (EEG) is the most dominant method for detecting epileptic seizures. However, the existing techniques use single-channel EEGs from public databases and the sample size is small. OBJECTIVE: This study proposes a strategy to distinguish multichannel EEGs for health control, particularly the interictal and ictal multichannel EEGs of epileptic patients. METHOD: We calculated five features (variance, Pearson correlation coefficient, Hoeffding’s D measure, Shannon entropy, inter-quartile range), which are based on maximal overlap discrete wavelet transform. These features were then fed into linear discriminant analysis for classification purposes. Finally, the proposed method was tested on data on 34 healthy people, 21 interictal patients and 30 ictal patients taken from a hospital. RESULTS: Our experimental results show that the accuracy between healthy and epileptic seizures was 96.88% and the area under the curve (AUC) is 1. The accuracy between interictal and epileptic seizures was 94.12% and the AUC was 0.97. We also obtained an accuracy and AUC equal to 1 for discrimination of interictal EEGs from normal. Finally, we obtained an AUC of 0.83 and an accuracy of 85.88% for discrimination in these three classes. Therefore, our study achieves sufficient performance. CONCLUSIONS: Our proposed method can serve as an auxiliary tool for clinicians who wish to make clinical decisions and reduces the burden of detecting epileptic seizures.
Keywords: MODWT, classification, electroencephalogram signals, LDA, epileptic seizures
DOI: 10.3233/THC-181548
Journal: Technology and Health Care, vol. 28, no. 1, pp. 23-33, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl