Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Other
Authors: Cho, Myoung-Ocka | Kim, Subina | Lee, Ji Yeonb | Oh, Jong Hyunb | Kim, Jee Youngb | Bong, Sung Rokb | Chung, Chanilb | Kim, Jung Kyungc; *
Affiliations: [a] Department of Mechanical Engineering, Graduate School, Kookmin University, Seoul 02707, Korea | [b] NanoEntek, Seoul 08389, Korea | [c] School of Mechanical Engineering and Department of Integrative Biomedical Science and Engineering, Graduate School, Kookmin University, Seoul 02707, Korea
Correspondence: [*] Corresponding author: Jung Kyung Kim, School of Mechanical Engineering, Kookmin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 02707, Korea. Tel.: +82 2 910 4767; Fax: +82 2 910 4839; E-mail: jkkim@kookmin.ac.kr.
Abstract: BACKGROUND:Although AIDS-related mortality has declined since the introduction of antiretroviral therapy (ART), HIV/ AIDS patients are predominantly present in developing countries that lack high-cost diagnostic devices and human expertise. OBJECTIVE: New methods for counting CD4+ cells cost-effectively are needed to replace conventional flow cytometry-based diagnosis. METHODS: We developed a CD4+ cell analyzer, ADAMII, which is a benchtop fluorescence image-based CD3+/4+ cell counting analyzer. It bears a three-channel light source and performs CD3+/4+ counting assays. The automatic 3D stage captures a maximum of 136 images that are subsequently processed and analyzed using a software integrated into the system. RESULTS: Results obtained using ADAMII were compared with data obtained by conventional methods using a FACSCalibur flow cytometer and the point-of-care PIMA CD4 analyzer. Both comparisons between ADAMII vs. FACS and ADAMII vs. PIMA data yielded a strong correlation with an R2 value of 0.98, which ensures the feasibility of CD4 test by ADAMII. CONCLUSIONS: The proposed method using ADAMII can be easily employed in resource-limited areas to replace conventional flow cytometers, which are expensive and require highly trained staff.
Keywords: CD4+ cells, HIV, AIDS, point-of-care, cell analyzer, image cytometry
DOI: 10.3233/THC-181354
Journal: Technology and Health Care, vol. 26, no. 5, pp. 867-871, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl