Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Do Hyuna | An, Duk-Hyunb | Yoo, Won-Gyub; *
Affiliations: [a] HIP&MAL Laboratory, Department of Rehabilitation Science, Inje University, Gimhae, Korea | [b] Department of Physical Therapy, College of Biomedical Science and Engineering, Inje University, Gimhae, Korea
Correspondence: [*] Corresponding author: Won-Gyu Yoo, Department of Physical Therapy, College of Biomedical Science and Engineering, Inje University, 197 Inje-ro, Gimhae, Gyeongsangnam-do 621-749, Korea. Tel.: +82 55 320 3994; E-mail: won7y@inje.ac.kr.
Abstract: OBJECTIVE: The main purpose of this study was to measure the peak acceleration of the upper limb (UL) during reaching, and to calculate correlations between peak acceleration data and functional test results in children with cerebral palsy (CP). METHODS: We recruited 15 children with CP (8 boys and 7 girls) and measured peak acceleration and function as revealed by the Jebsen Taylor Hand Function Test (JTHF), the Quality of Upper Extremity Skills Test (QUEST), the Box and Blocks Test (BBT), and the ABILHAND-Kids questionnaire. We calculated correlations between peak acceleration data and scores on the functional tests. RESULTS: The peak acceleration of the more-affected UL was significantly higher than that of the less-affected UL (p< 0.05). The peak acceleration data were positively correlated with JTHFT scores. On the other hand, the peak acceleration data were negatively correlated with QUEST, BBT, and ABILHAND-Kids scores. The test-retest reliability of the peak acceleration was excellent, with an intra-class correlation coefficient (ICC) 0.87–0.98. CONCLUSIONS: Peak acceleration data correlated with UL functional test results; as this proved to be reliable, the tri-axial accelerometer is a clinically useful assessment tool for evaluating UL movement. Therefore, our results suggest that measurement of acceleration using a tri-axial accelerometer is appropriate when clinicians quantify UL movement during therapeutic rehabilitation in clinical settings.
Keywords: Correlation, peak acceleration, reaching, reliability, tri-axial accelerometer
DOI: 10.3233/THC-171148
Journal: Technology and Health Care, vol. 26, no. 3, pp. 429-435, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl