Abstract: Using the volatile anaesthetic isoflurane as a marker substance a gas chromatographic method for analysis of exhaled gas in mechanically ventilated patients was evaluated. Twelve patients with and 10 patients without preceding isoflurane exposure and seven blank respiratory circuits were investigated. Respiratory gas was sampled at four different sites in the respiratory tubing system. Analysis of volatile components was based upon adsorption onto activated charcoal, desorption by means of microwave energy, gas chromatographic separation and flame ionisation or mass spectrometric detection. Isoflurane concentrations in the blank respiratory circuits, in the control group, and in the inspiratory limb of patients with preceding isoflurane inhalation were at the limit of detection (<10−12 mol/l). In the isoflurane group, isoflurane concentrations in the inspiratory and expiratory limb differed considerably. Using the method described, substances at very low concentrations could be identified as originating in the patient or as coming from the gas delivery system.
Keywords: Breath analysis, isoflurane, mechanical ventilation
DOI: 10.3233/THC-1999-7102
Journal: Technology and Health Care, vol. 7, no. 1, pp. 29-37, 1999
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl