Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Shuangyana | Teng, Jingb | Qi, Xianghuac | Wei, Shoushuia; * | Liu, Chengyua; *
Affiliations: [a] Institute of Biomedical Engineering, School of Control Science and Engineering, Shandong University, Jinan 250061, Shandong, China | [b] Department of Internal Traditional Chinese Medicine, Shandong University of Traditional Chinese Medicine, Jinan 250011, Shandong, China | [c] Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250061, Shandong, China
Correspondence: [*] Corresponding authors: Shoushui Wei and Chengyu Liu, both in Institute of Biomedical Engineering, School of Control Science and Engineering, Shandong University, Jinan 250061, Shandong, China. Tel.: +86 531 88395827; Fax: +86 531 88395827; E-mail:sswei@sdu.edu.cnandbestlcy@sdu.edu.cn
Abstract: BACKGROUND: The usefulness of heart rate variability (HRV) in the clinical research has been verified in numerous studies. However, it is controversy that using pulse rate variability (PRV) as a surrogate of HRV in different clinical applications. OBJECTIVE: We aimed to investigate whether PRV extracted from finger pulse photoplethysmography (Pleth) signal could substitute HRV from ECG signal during different sleep stages by analyzing the common time-domain, frequency-domain and non-linear indices. METHODS: Seventy-five sleep apnea patients were enrolled. For each patient, ECG and Pleth signals were simultaneously recorded for the whole night using Alice Sleepware Polysomnographic System and the sleep stage signals were automatically calculated by this System. Time-domain, frequency-domain and non-linear indices of both HRV and PRV were calculated for each sleep stage. RESULTS: Mann-Whitney U-test showed that for both time-domain and frequency-domain indices, there were no statistical differences between HRV and PRV results during all four sleep stages. For non-linear indices, sample entropy reported statistical differences between HRV and PRV results for N1, N2 and REM sleeps (all P< 0.01) whereas fuzzy measure entropy only reported statistical differences for REM sleep (P< 0.05). SDNN, LF and LF/HF indices decreased for both HRV and PRV with the sleep deepening while HF and non-linear indices increased. In addition, there were strong and significant correlation between HRV and PRV indices during all four sleep stages (all P< 0.01). CONCLUSIONS: PRV measurement could present the similar results as HRV analysis for sleep apnea patients during different sleep stages.
Keywords: Heart rate variability, pulse rate variability, sleep apnea, sleep stage
DOI: 10.3233/THC-161283
Journal: Technology and Health Care, vol. 25, no. 3, pp. 435-445, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl