You are viewing a javascript disabled version of the site. Please enable Javascript for this site to function properly.
Go to headerGo to navigationGo to searchGo to contentsGo to footer
In content section. Select this link to jump to navigation

2D biological representations with reduced speckle obtained from two perpendicular ultrasonic arrays

Abstract

Ultrasound diagnosis is a widely used medical tool. Among the various ultrasound techniques, ultrasonic imaging is particularly relevant. This paper presents an improvement to a two-dimensional (2D) ultrasonic system using measurements taken from perpendicular planes, where digital signal processing techniques are used to combine one-dimensional (1D) A-scans were acquired by individual transducers in arrays located in perpendicular planes. An algorithm used to combine measurements is improved based on the wavelet transform, which includes a denoising step during the 2D representation generation process. The inclusion of this new denoising stage generates higher quality 2D representations with a reduced level of speckling. The paper includes different 2D representations obtained from noisy A-scans and compares the improvements obtained by including the denoising stage.

References

[1] 

Galloway R.L., , McDermott B.A., , Thurstone F.L., A frequency diversity process for speckle reduction in real-time ultrasonic images, IEEE Transactions Ultrasonic, Ferroelectric and Frequency Control 35: ((1988) ), 45-49.

[2] 

Loizou C.P., , Pattichis C.S., et al., Comparative Evaluation of Despeckle Filtering In Ultrasound Imaging of the Carotid Artery, IEEE Transactions Ultrasonic, Ferroelectric and Frequency Control 52: ((2005) ), 1653-1669.

[3] 

Zhanga J., , Lina G., , Wua L., , Wanga C., , Cheng Y., Wavelet and fast bilateral filter based de-speckling method for medical ultrasound images, Biomedical Signal Processing and Control 18: ((2015) ), 1-10.

[4] 

Fu X., , Wang Y., , Chen L., , Tian J., An image despeckling approach using quantum-inspired statistics in dual-tree complex wavelet domain, Biomedical Signal Processing and Control 18: ((2015) ), 30-35.

[5] 

Dahdouh S., , Dubois M., et al., A 1D wavelet filtering for ultrasoundimages despeckling. Proc of SPIE 7629: ((2010) ), 1-9, DOI: 10.1117/12.844388.

[6] 

Nakayama K., , Ohyama W., et al., Speckle reduction of echocardiogramsvia wavelet shrinkage of ultrasonic RF signals. 13th ICBME 23: ((2009) ), 395-398.

[7] 

Zhang Y., , Wang Y.Y., et al., Doppler ultrasound signal denoisingbased on wavelet frames, IEEE Transactions Ultrasonic, Ferroelectric and Frequency Control 48: ((2001) ), 709-716.

[8] 

Liu B., , Wang Y., , Wang W., Spectrogram enhancement algorithm: A soft thresholding-based approach, Ultrasound Med Biol 25: ((1999) ), 839-846.

[9] 

Donoho D.L., , Johnstone I.M., Ideal spatial adaptation by waveletshrinkage, Biometrika 81: ((1994) ), 425-455.

[10] 

Donoho D.L., , Johnstone I.M., et al., Wavelet shrinkage: Asymptotia, J R Stat Soc B 57: ((1995) ), 301-369.

[11] 

Donoho D.L., , Johnstone I.M., Adapting to unknown smoothnessvia wavelet shrinkage, J Am Stat Assoc 90: ((1995) ), 1200-1224.

[12] 

Wang F., , Ji Z., Application of the Dual-tree ComplexWaveletTransform in Biomedical Signal Denoising, Bio-Medical Materials and Engineering 24: ((2014) ), 109-115; DOI: 10.3233/BME-130790.

[13] 

San Emeterio J.L., , Rodriguez-Hernandez M.A., Wavelet denoising of ultrasonic A-scans for detection of weak signals, 19th International Conference on Systems, Signals and Image Processing (IWSSIP), Vienna, Austria ((2012) ), 54-57.

[14] 

Coifman R.R., , Donoho D.L., Translation-invariant de-noising, Lect Notes Stat 103: ((1995) ), 125-150.

[15] 

Pardo E., , San Emeterio J.L., et al., Shift invariant wavelet denoisingof ultrasonic traces, ActaAcust United Ac 94: ((2008) ), 685-693.

[16] 

San Emeterio J.L., , Rodriguez-Hernandez M.A., Wavelet Cycle Spinning Denoising of NDE Ultrasonic Signals Using a Random Selection of Shifts, Journal Nondestructive Evalaluation 34: ((2015) ), 270, DOI: 10.1007/s10921-014-0270-8. %

[17] 

Rodriguez-Hernandez M.A., , %San Emeterio J.L., %Noise Reduction Using Wavelet %Cycle Spinning. Analysis of Useful Periodicities in the z-Transform Domain, %Signal Image Video Processing, in press, DOI: 10.1007/s11760-015-0762-8.

[18] 

Rodriguez-Hernandez M.A., , San Emeterio J.L., Noise Reduction Using Wavelet Cycle Spinning. Analysis of Useful 189 Periodicities in the z-Transform Domain, Signal Image Video Processing, 10: ((2016) ), 519-526; DOI: 10.1007/s11760-015-0762-8.

[19] 

Meyer A.W., , Candy J.V., Iterative processing of ultrasonic measurements to characterize flaws in critical optical components IEEE Trans. Ultrason. Ferroelect. Freq. Control 8: ((2002) ), 1124-1138.

[20] 

Reguieg D., , Padilla F., et al., Ultrasonic transmission device based on crossed beam forming, Proc. IEEE Ultrasonics Symp. ((2006) ), 2108-2111.

[21] 

Zhu H.J., , Yang P., , Yao T.B., 3D reconstruction of ultrasound scanned data for tissue mimicking material sample, Bio-Medical Materials and Engineering 24: ((2014) ), 2771-2781, DOI: 10.3233/BME-141095.

[22] 

Rodriguez-Hernandez M.A., , Ramos A., , San Emeterio J.L., Wavelet-based 2D fusing of ultrasonic pulse-echo traces measured from two arrays radiating orthogonal beams, Measurement Science and Technology 22: ((2011) ), 1-14, DOI: 10.1088/0957-0233/22/10/105701.

[23] 

Rodriguez-Hernandez M.A., , Ramos A., , San Emeterio J.L., Localization of Isolate Flaws by Combination of Noised Signals Detected from Perpendicular Transducers, NDT and E International 37: ((2004) ), 345-352.

[24] 

Donoho D.L., De-noising by soft thresholding, IEEE Transactions on Information Theory 41: ((1995) ), 613-627.