Authors: Reuzé, P.a; * | Coatrieux, J.L.a | Luo, L.M.b | Dillenseger, J.L.b
Affiliations: [a] Laboratoire Traitement du Signal et de l'Image Campus de Beaulieu, Université de Rennes I, 35042 Rennes France | [b] Vision and Image Processing Laboratory Southeast University, Nanjing, China
Correspondence: [*] Corresponding author.
Abstract: This paper describes a new method for the three-dimensional (3-D) tracking and the quantification of blood vessels from magnetic resonance angiography (MRA). The approach is based on 3-D geometrical moments and consists of the following steps: (1) interactive selection of 3-D seed points; (2) automatic tracking of the vessels; (3) local computation of both diameter and orientation; (4) rendering of the vessels. This detection and estimation scheme has been validated on simulated and real data.
Keywords: Magnetic resonance angiography, Detection, Quantification, Tracking, Rendering
DOI: 10.3233/THC-1993-1209
Journal: Technology and Health Care, vol. 1, no. 2, pp. 181-188, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl