Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kaluzynski, K.a; * | Lesniak, B.a | Mikolajczyk, K.a | Liepsch, D.b
Affiliations: [a] Institute for Precision and Biomedical Engineering, Warsaw University of Technology, 8 Chodkiewicza str., 02–525 Warsaw, Poland | [b] Laboratory for Fluidmechanics, Fachhochschule München, Lothstrasse 34, 80335 Munich, Germany
Correspondence: [*] Corresponding author: K. Kaluzynski, Ph.D. Tel.: +48 22 660 8270; Fax: +48 22 48 37 64; E-mail: kaluz@mp.pw.edu.pl.
Abstract: In this study properties are concerned of ultrasonic Doppler spectra recorded distal to an irregularity localised in the internal carotid artery of a true-to-scale elastic model of a severely stenosed carotid bifurcation. Four models differing in irregularity were obtained by melting graded holes in the original wax cast, about 5–7 mm distal to the bifurcation. Velocity data were collected using an HP Sonos 2500 ultrasonograph working in pulsed Doppler mode. The observed effect of the irregularity with respect to the smooth wall model consisted in: (1) presence of a reduced flow zone 15 mm distal to the severe irregularity situated at the outer wall of the model in the ICA branch; (2) presence of a recirculation zone 15 mm distal to the severe irregularity situated at the inner wall of this model; (3) negative values of the measure of symmetry of the Doppler spectrum and (4) decreased values of relative width of Doppler spectra obtained 25 mm distal to the bifurcation in models with severe irregularity. The alterations of flow distribution and Doppler spectra depend on the geometry of the model under investigation and this study provides an indication as to what phenomena can happen in a model of stenosed carotid bifurcation with irregular lesion surface and how these phenomena may affect the ultrasonic Doppler spectra. Such information could be used in the evaluation of the risk of cerebral embolism.
Keywords: Doppler ultrasound, spectral analysis, blood flow velocity, carotid artery stenosis, lesion surface irregularity, cerebral embolism
DOI: 10.3233/THC-1997-5303
Journal: Technology and Health Care, vol. 5, no. 3, pp. 199-206, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl