Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wassilew, G.I.a; * | Hasart, O.a | Heller, M.O.b; d | Perka, C.a | Südhoff, I.c | Janz, V.a | Seeger, J.B.a | König, C.b; d
Affiliations: [a] Charité – Orthopedic Department, Center for Musculoskeletal Surgery, Berlin, Germany | [b] Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité, Germany | [c] Aesculap AG, Tuttlingen, Germany | [d] Universitätsmedizin Berlin, Center for Sports Science and Sports Medicine Berlin, Berlin, Germany
Correspondence: [*] Corresponding author: Georgi I. Wassilew, MD, Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany. Tel.: +49 30 450615179; Fax: +49 30 450515922; E-mail: georgi.wassilew@charite.de.
Abstract: Introduction:The present feasibility study examined the use of an ultrasound-based navigation system (UNS) for reliability of measurement the positions of both the femoral and acetabular components, a prerequisite to adjust the combined anteversion with sufficient accuracy when using a femur-first approach in total hip arthroplasty. Method:Using a UNS, five investigators performed five measurements of the posterior femoral condyles and the anterior pelvic planes (APP) of two cadavers with different body mass index. Deviations in stem and acetabular anteversion resulting from varying acquisition of the respective landmarks were determined relative to the reference measures of anteversion determined in the same cadavers from computed tomography (CT) scans. Here, both a freehand and guided ultrasound measurement methods were used to acquire the posterior femoral condyles. Femoral and acetabular anteversion values were added in order to estimate the combined anteversion of the reconstructed hip. Results:Using an UNS, variations in the freehand technique for the acquisition of the posterior femoral condyles resulted in a mean error in the anteversion of the femoral component of −1.5° (SD 3.4°; −10.8° to 7.0°) while the mean error was −0.9° (SD 3.1°; −7.3° to 10.2°) when the UNS provided additional support to standardize the orientation of the UNS probe. In all cases, UNS navigation enabled to achieve combined anteversion values that fell within a clinically acceptable error range of less than ± 12.5° compared to the CT measures. Conclusion:Our investigations suggest that the anteversion of stem and cup can be measured with accuracy sufficient enough to utilize the concept of combined anteversion using UNS. Hence, the advantage of utilizing UNS's in a femur-first approach is the ability to intraoperatively compensate for deviations from the targeted anteversion of the stem (which is often difficult to control) by adjusting the acetabular anteversion in the final step of the implantation. In doing so, the placement of the components follows the concept of combined anteversion. Avoiding extreme anteversion values of combined anteversion could be an important step towards reducing post-operative complications following total hip arthroplasty (THA).
Keywords: Ultrasound, computer navigation, combined anteversion, cadaver, accuracy
DOI: 10.3233/THC-2012-00699
Journal: Technology and Health Care, vol. 20, no. 6, pp. 565-573, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl