Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wakamatsu, H.a; * | Utsuki, T.a | Mitaka, C.b | Ohno, K.c
Affiliations: [a] Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan | [b] Intensive Care Unit, Tokyo Medical and Dental University, Tokyo, Japan | [c] Department of Neurosurgery, Tokyo Medical and Dental University, Tokyo, Japan
Correspondence: [*] Address for correspondence: H. Wakamatsu, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan. Tel.: +81 3 5803 5367; Fax: +81 3 5803 0162; E-mail: wakamatsu.bse@tmd.ac.jp.
Abstract: Automatic control systems of brain temperature for water surface-cooling were first-ever applied to the brain hypothermic treatment of patients. A patient in ICU was regarded as a unity controlled system with an input (temperature of water into blanket) and an output (tympanic membrane temperature). The proposed algorithm of optimal-adaptive and fuzzy control laws inclusive of our developed cooling and warming machine were well confirmed during the hypothermic course to keep brain temperature of patients within its allowable range. It was well controlled without much influence due to room temperature, metabolic and circulatory change caused by various medical treatments including the effect of nonlinear and time-varying characteristics of individual patients. The clinical control of brain temperature was almost continuously performed in around 10 days, under the brain temperature between 35°C and 37°C scheduled by physicians according to the state of patients. Their state had been monitored during the therapeutic course of pharmacological treatment with almost everyday examinations by CT imaging, referring various vital signs inclusive of the temperature of urinary bladder with continuous measurement of intracranial pressure by a catheter placement in cerebral sinus. The patients had good recovery to their rehabilitation after mild hypothermia by the proposed automatic control systems.
Keywords: Brain hypothermia, brain temperature, clinical practice, optimal-adaptive control system, fuzzy control system
DOI: 10.3233/THC-2010-0581
Journal: Technology and Health Care, vol. 18, no. 3, pp. 181-201, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl