Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dendorfer, S.a; * | Maier, H.J.b | Hammer, J.a
Affiliations: [a] University of Applied Sciences Regensburg, Regensburg, Germany | [b] University of Paderborn, Paderborn, Germany
Correspondence: [*] Address for correspondence: Sebastian Dendorfer, Labor fuer Werkstoffkunde und Metallographie, Fachhochschule Regensburg, Galgenbergstrasse 30, 93053 Regensburg, Germany. E-mail: sdendorfer@lwm-regensburg.de.
Abstract: Repetitive cyclic loading from daily activities is reported to induce fatigue damage and microcracking in bone structures. In terms of osteoporotic structures or in cases of serious damage of skeleton segments and the replacement by metallic implants the degree of damage due to cyclic loading will be even more pronounced. It is generally assumed that fatigue induced cracking and crack propagation essentially act as driving forces for complex physiological phenomena such as remodelling processes of bones and the adaptation to applied loads. In cases where the crack propagation rate exceeds the remodelling velocity, sudden and unexpected fracture of the bone is observed. Especially for implant reinforced structures the deviation in stiffness to the bone material can induce high peak stresses and accelerate crack propagation. Whereas, for cortical bone the mechanical behaviour under cyclic loading is sufficiently described, only rough data are available for trabaecular structures. In this study the deformation behaviour of bovine vertebra trabecular bone specimens is investigated under cyclic compressive loading. A powerlaw relationship was found between the applied load ratio and cycles to failure. A linear decrease of maximum, integral strains at failure with increasing applied load ratio was observed. Optical deformation measurement of the surface strains revealed that low strains (0–1 increasing applied load ratio whereby the higher strains behave directly opposite. This indicates that different failure mechanisms are acting at low cycle and high cycle fatigue, respectively.
DOI: 10.3233/THC-2006-14611
Journal: Technology and Health Care, vol. 14, no. 6, pp. 549-556, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl