Article type: Research Article
Authors: Citak, M.a; * | Kendoff, D.a | Wanich, T.b | Pearle, A.b | Singhai, R.c | Krettek, C.a | Hüfner, T.a
Affiliations: [a] Trauma Department, Hannover Medical School, Hannover, Germany | [b] Orthopaedic Department, Hospital for Special Surgery, New York, USA | [c] Department of Orthopaedics, Sultan Qaboos Hospital, Oman
Correspondence: [*] Address for correspondence: Musa Citak, MD, Trauma Department, Hannover Medical School, Carl- Neubergstr. 1, 30655 Hannover, Germany. Tel.: +49 511 532 2026; Fax: +49 511 532 5788; E-mail: mcitak@web.de.
Abstract: Computer-assisted treatments have become increasingly common. Consequently, there is an increased desire for navigation methods with simplified workflow. Anatomic-based pair-point registration is often mentioned as a source of error. Alternatively, the use of preoperatively implanted markers for registration remains complex. The self-acting registration of Iso-C-3D at the moment of data acquisition can reduce essential errors. The aim of this study was to evaluate the effect of reference placement on accuracy, and to determine the maximum acceptable distance between the reference and a given isocentre. This study demonstrates the interdependence of the reference distance on the region of interest (ROI). The mean error of registration amounts to 0.04 mm (0.04–0.05 mm) up to a distance of 200 mm and beyond 0.25 mm (0.24–0.26) for distances beyond 200 mm. The accuracy was significantly lower (p<0.0001) with a distance more than 200 mm. For optimal accuracy when utilizing navigation for pelvic and long bone surgery, the reference base should not been placed at a distance more than 200 mm from the isocentre of interest.
Keywords: Iso-C 3D navigation, precision, registration, computer assisted orthopaedic surgery, reference base
DOI: 10.3233/THC-2006-14602
Journal: Technology and Health Care, vol. 14, no. 6, pp. 473-478, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl