Authors: Dammak, M.a | Shirazi-Adl, A.b | Zukor, D.J.c
Affiliations: [a] LAboratoire des Systemes ElectroMécaniques (LASEM), Ecole Nationale d'Ingenieurs de Sfax, Tunisie | [b] Division of Applied Mechanics, Department of Mechanical Engineering, Ecole Polytechnique, Montréal, Canada | [c] Department of Orthopaedic Surgery, Jewish General Hospital and McGill University, Montréal, Canada
Abstract: The short- and long-term success of tibial cementless implants depend on the initial fixation stability often provided by posts and screws. Excessive relative interface motions are known to inhibit bone ingrowth and, hence, biologic fixation. In the present study, the stability of two cementless tibial implants under static and cyclic loading was studied. An apparatus was developed to perform compression tests on tibial components fixed by screws or posts onto resurfaced tibiae. Motion transducers were placed to record liftoff and subsidence displacements. A load of 1000 N was eccentrically applied on the medial plateau via the femoral component. The response was measured under static and repetitive loading up to 4000 cycles at 1 Hz. Experimental results showed that the screw fixation yielded the stiffer response and, hence, provided greater initial stability. The tibial component fixed with posts demonstrated larger lift off displacements. Comparison of measured results of static tests before and after fatigue indicated that the load-displacement behavior was not significantly affected by the cyclic fatigue loading under 1000 N up to 4000 cycles at 1 Hz. Nevertheless, much larger permanent displacements were recorded for the post fixation systems. In contrast to screw fixation, posts fixation systems demonstrated marked deterioration under larger compression loads of ~2000 N.
Keywords: fixation, knee implant, screw, posts, micro-motion
DOI: 10.3233/THC-2003-11404
Journal: Technology and Health Care, vol. 11, no. 4, pp. 245-252, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl