Affiliations: School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798. Tel.: 65 6790 4433; Fax: 65 6791 1859; E-mail: mnader@ntu.edu.sg | Department of Mechanical Engineering, Virginia Polytechnic Institute, 123 Randolph Hall, Blacksburg, VA 24061, USA. Tel.: +1 540 231 4920; Fax: +1 540 231 9100; E-mail: ahmadian@vt.edu
Note: [] Corresponding author
Abstract: Passive fluid mounts are commonly used in the automotive and aerospace applications to isolate the cabin from the engine noise and vibration. Due to manufacturing and material variabilities, no two identical fluid mount designs act the same. So, fluid mounts are tuned one by one before it is shipped out to customers. In some cases, for a batch of fluid mounts manufactured at the same time, one is tuned and the rest is set to the same settings. In some cases they are shipped as is with its notch frequency not being in its most optimum location. Since none of the passive fluid mount parameters are controllable, the only way to tune the mount is to redesign the mount by changing fluid, changing inertia track length or diameter, or changing rubber stiffness. This trial and error manufacturing process is very costly. To reduce the fluid mount notch frequency tuning cycle time, a new fluid mount design is proposed. In this new fluid mount design, the notch frequency can be easily modified without the need for any redesigns. In this paper, the new design concept, and its mathematical model and simulation results will be presented.
Journal: Shock and Vibration, vol. 11, no. 1, pp. 21-32, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl