Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Elgebaly, Reem H.a; * | Rageh, Monira M.a | Adel, Mahmoudb
Affiliations: [a] Department of Biophysics, Faculty of science, Cairo University, Cairo, Giza, Egypt | [b] Department of Critical care medicine, Faculty of Medicine, Cairo University, Cairo, Giza, Egypt
Correspondence: [*] Corresponding author: Reem H. Elgebaly, Department of Biophysics, Faculty of science, Cairo University, Cairo, Giza, Egypt. E-mail:r_elgebaly@msn.com
Abstract: BACKGROUND: There are various physical factors that limit the quality of the Single Photon Emission Computed Tomography (SPECT) images such as number of frames per projection, number of projections per scan and time per projection in gated myocardial SPECT scan. OBJECTIVE: The aim of the present work was to evaluate physical acquisition parameters affecting the cardiac imaging to optimize the patient's examination time and image quality that are acquired with the gamma camera and workers radiation protection (through reducing time of radiation exposure) in cardiac SPECT facility. Cardiac functional parameters like ejection fraction (EF), end diastole volume (EDV), end systole volume (ESV) and total perfusion defect (TPD) were evaluated. METHODS: Thirty patients were divided into three groups as follows: 1- Group (1): contains two sub-groups, one scanned with 8 frames per projection, the other with 16 frames per projection. 2- Group (2): contains two sub-groups, one scanned with 32 projections per scan, the other with 16 projections per scan. 3- Group (3): contains two sub-groups, one scanned at a time per projection of 20 s and the other scanned at 10 s per projection. Parameters such as the Ejection Fraction (EF), End Diastole Volume (EDV), End Systole Volume (ESV) and Total Perfusion Defect (TPD) in SPECT were compared for each group. RESULTS: There was insignificant difference in the EF, EDV, ESV and TPD between the different groups concerning the number of frames per projection, number of projections per scan and time per projection. CONCLUSION: The reduction of scan time to half or the number of projections per scan to half or increasing the number of frames per scan from 8 to 16 at the same duration has insignificant effect in the cardiac functional parameters used with gated SPECT scan.
Keywords: Gated SPECT, physical acquisition parameters, filtered back projections (FBP), gamma camera
DOI: 10.3233/XST-150500
Journal: Journal of X-Ray Science and Technology, vol. 23, no. 4, pp. 453-461, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl