Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Komarskiy, Alexander Alexandrovich; * | Korzhenevskiy, Sergey Romanovich | Ponomarev, Andrey Viktorovich | Komarov, Nikita Alexandrovich
Affiliations: The Institute of Electrophysics, Russian Academy of Sciences, Ekaterinburg, Russia
Correspondence: [*] Corresponding author: Komarskiy Alexander; Ph.D., scientific researcher. Institute of Electrophysics of the Ural Branch of the Russian Academy of Sciences. 106 Amundsena Street, Ekaterinburg, 620016, Russia. Tel.: +79630414892; E-mail: aakomarskiy@gmail.com.
Abstract: BACKGROUND:Traditionally, X-ray systems for capturing moving objects consist of a continuous X-ray source and a detector that operates at a predetermined frame rate. OBJECTIVE:This study investigates the possibility of using pulsed X-ray source with an inductive energy storage device and a semiconductor opening switch for shooting moving objects. METHODS:The study uses a high-voltage pulse generator that has the following parameters namely, the pulse voltage amplitude up to 320 kV, the pulse current up to 240 A, the current pulse duration of about 50 ns, and the pulse repetition rate up to 2 kHz. The duration and intensity of glow for standard CsI:Tl and Gd2O2S:Tb X-ray phosphors after their irradiation with X-ray flashes of about 50 ns duration are investigated. After X-ray radiation is converted into light, the signal is recorded using semiconductor detectors. We acquired several images of an object moving at a speed of about 20 m/s. A semiconductor detector with phosphor, which operates in the mode of continuous signal accumulation, is used. RESULTS:When using the pulsed X-ray source and phosphors with a short afterglow, the individual frames can be obtained at the pulse repetition rate of several kilohertz, and the detector does not contain the residual luminescence from the previous frame by the arrival of the next frame. CONCLUSIONS:The X-ray source shows good pulse-to-pulse reproducibility of X-rays, and can be used to capture objects in motion at a frame rate of several kHz.
Keywords: Pulsed X-ray source, speed shooting, X-ray flash, semiconductor opening switch, inspection control, CT scan
DOI: 10.3233/XST-210873
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 4, pp. 567-576, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl