Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Young-Pyoa | Park, Yong-Pilb | Cheon, Min-Woob; *
Affiliations: [a] Department of Research and Development, Ecoray Co. Ltd., Nam-myeon, Jangseong-gun, Jeollanam-do, Republic of Korea | [b] Department of Health Administration, Dongshin University, Geonjae-ro, Na-Ju, Jeollanam-do, Republic of Korea
Correspondence: [*] Corresponding author: Min-Woo Cheon, Department of Health Administration, Dongshin University, Geonjae-ro, Na-Ju, Jeollanam-do, 58245, Republic of Korea. E-mail: mwcheon@dsu.ac.kr.
Abstract: Mobile X-ray device is widely employed because it is useful for diagnosis in patients having mobility difficulties and in medical emergencies. As various devices for X-ray generation have continued to be developed, X-ray devices can now be used more safely and effectively. However, mobile X-ray devices generate relatively low X-ray doses due to the limitation of the power input. Therefore, the use of mobile X-ray devices is limited to thin parts of body. In this study, a new device was designed in order to increase the usefulness of mobile X-ray devices by offsetting the weaknesses of the existing mobile X-ray devices, rendering them useable independently. A supercapacitor and battery were used as the internal power source for the X-ray generation in the manufactured device. The pulse width modulation (PWM) method is applied to control the tube voltage and current required for generating the X-ray, and the pulse frequency modulation (PFM) method is applied to the control to generate the high voltage in order to enhance the precision and efficiency. The manufactured X-ray device was used to evaluate the control signal, frequency, and output characteristics according to changes in tube voltage and current. Based on the results of X-ray generation, it is confirmed that precise control was achieved by X-ray generation increases linearly with increasing tube voltage and tube current. This means that precise control of the manufactured mobile X-ray device is passible. In addition, the study confirmed that stable output was achieved by checking the tube voltage, tube current and exposure rate during the exposure times by high power condition.
Keywords: Mobile X-ray, supercapacitor, internal power, exposure rate
DOI: 10.3233/XST-18389
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 5, pp. 777-784, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl