Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Li, Jie | Zhang, Wenkun | Cai, Ailong | Wang, Linyuan | Liang, Ningning | Zheng, Zhizhong | Li, Lei | Yan, Bin; *
Affiliations: National Digital Switching System Engineering and Technological Research Center, Zhengzhou, P.R. China
Correspondence: [*] Corresponding author: Bin Yan, National Digital Switching System Engineering and Technological Research Center, Zhengzhou, 450002, P.R. China. E-mail: ybspace@hotmail.com.
Abstract: Since the excessive radiation dose may induce potential body lesion, the low-dose computed tomography (LDCT) is widely applied for clinical diagnosis and treatment. However, the dose reduction will inevitably cause severe noise and degrade image quality. Most state-of-the-art methods utilize a pre-determined regularizer to account for the prior images, which may be insufficient for the most images acquired in the clinical practice. This study proposed and investigated a joint regularization method combining a data-driven tight frame and total variation (DDTF-TV) to solve this problem. Unlike the existing methods that designed pre-determined sparse transform for image domain, data-driven regularizer introduced a learning strategy to adaptively and iteratively update the framelets of DDTF, which can preferably recover the detailed image structures. The other regularizer, TV term can reconstruct strong edges and suppress noise. The joint term, DDTF-TV, collaboratively affect detail preservation and noise suppression. The proposed new model was efficiently solved by alternating the direction method of the multipliers. Qualitative and quantitative evaluations were carried out in simulation and real data experiments to demonstrate superiority of the proposed DDTF-TV method. Both visual inspection and numerical accuracy analysis show the potential of the proposed method for improving image quality of the LDCT.
Keywords: Low-dose computed tomography, iterative image reconstruction, data-driven tight frame, total variation, alternating direction method
DOI: 10.3233/XST-18379
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 5, pp. 785-803, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl