Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kowaluk, Tomasz; * | Wożniak, Adam
Affiliations: Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Poland
Correspondence: [*] Correspondence to: Tomasz Kowaluk, Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, św. A. Boboli 8 st., 02-525 Warsaw, Poland. Tel.: +48 22 234 86 65; E-mail: t.kowaluk@mchtr.pw.edu.pl.
Abstract: The article presents and discusses results of an experimental study regarding the accuracy of measurements performed with X-ray CT scanners. One of the main factors affecting the measurement result is definition of the threshold value between the air and the material. In this study, the results of measurements using two methods to determine the threshold value namely, the newly developed method and a well-known and commonly used method of ISO50%, were compared. A novel method is based on the measurement of an additional reference workpiece. The correction value, based on the measurement, is determined, and then it takes account when determining the threshold value between the air and the material. The study was performed using two types of gauges. These were workpieces of a specified volume of material (consisting of reference balls) and with the defined values of linear dimensions (in the form of cubes and cylinder). Using five different CT scanners, the conducted study yielded increase in the accuracy of measurements by applying the developed method in relation to the ISO50% automated method. In the case of volumetric test workpieces, relative measurement errors were reduced by 3 to 10 times for metrological CT scanners and from 50 to 30% for defectoscopy CT scanners. In the case of linear dimension measurements, average measurement errors were reduced twice.
Keywords: X-ray tomography, air-material threshold, accuracy of measurements, ISO50%
DOI: 10.3233/XST-180400
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 5, pp. 833-841, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl