Article type: Research Article
Authors: Tan, Wenli | Zhan, Songhua | Yang, Shuohui | Zhuang, Yuan | Cheng, Ruixin | Zhan, Hongsheng
Affiliations: Radiology Department of Shuguang Hospital Affiliated to Shanghai University of TCM, Shanghai, China | Shu Guang Hospital, TCM Orthopedics and Traumatology, Shanghai, China
Note: [] Corresponding author: Songhua Zhan, Radiology Department of Shuguang Hospital Affiliated to Shanghai University of TCM, Shanghai 200021, China. Tel.: +86 158 2188 0788; Fax: +86 21 2025 6568; E-mail: zhansonghua2245@163.com
Abstract: OBJECTIVE: The aim of this study was to investigate the significance of the combined use of BMI and AEC in reducing the radiation dose of CT volume scans of the lumbar spine. METHODS: A prospective study was performed to continuously collect data from 50 patients (age range from 19 to 60 years, male versus female 20/30) whose BMIs were less than 25 kg/m^{2} (group A) and 50 patients (age range from 21 to 82 years, male versus female 24/26) whose BMIs were equal to or more than 25 kg/m^{2} (group B). The 50 patients in each group were randomly divided into 5 subgroups with each subgroup having lower radiation dose from subgroup 1 to 5. All the patients were performed lumbar spiral CT scans (GE LightSpeed VCT 64-slice scanner) and the scan parameters were different in different subgroups. Volume CT dose index (CTDIvol) was recorded. The qualities of the images were graded. The one-way ANOVA and Kruskal-Wallis test were done. RESULTS: Both in group A and B, there were significant differences in CTDIvol among the 5 subgroups (P< 0.001). The quality of the images in the 5 subgroups of group A didn't show statistical difference. The standard deviation (SD) and signal to noise ratio (SNR) values of the L4-5 psoas major muscles in subgroup 5 of group B was statistical different from the other 4 subgroups (P< 0.01). CONCLUSION: Use of BMI combined with AEC reduces radiation dosage, without compromising the image quality. For patients in group A and group B, parameters of subgroup 5 and subgroup 4 may respectively be applied for lower dose CT scanning.
Keywords: Body mass index (BMI), automatic exposure control (AEC), spiral CT, radiation dosage, lumbar vertebrae
DOI: 10.3233/XST-140455
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 6, pp. 697-706, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl