Authors: Mardirossian, George | Urie, Marcia | Fitzgerald, Thomas J. | Mayr, Nina | Montebello, Joseph | Lo, Yuan-Chynan
Affiliations: Radiation Oncology, Oklahoma University Health Sciences Center, Oklahoma City, OK 73104, USA. Radiation Oncology, University of Massachusetts Memorial Medical Center Worcester, MA 01655, USA
Note: [] Corresponding author: George Mardirossian, Ph.D., Oklahoma University Health Sciences Center, Department of Radiological Sciences, 1200 N. Everett Dr., Room B603, Oklahoma City, OK 73104, USA. Tel.: +1 405 271 6453; Fax: +1 405 271 8297; E-mail: George-Mardirossian@ouhsc.edu
Abstract: Commissioning of a Radionics miniature multi-leaf collimator (MMLC) for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) is reported. With single isocenter and multi static fields, the MMLC can provide better conformity of dose distributions to the target and/or irregularly shaped target volumes than standard arc (circular) field beams with multiple isocenters. Advantages offered by the MMLC over traditional LINAC based SRS and SRT includes greatly improved dose homogeneity to the target, reduced patient positioning time and reduced treatment time. In this work, the MMLC is attached to a Varian 2300 C/D with Varian 80-leaf multi-leaf collimator. The MMLC has 62 leaves, each measured to a width of 3.53 mm at isocenter, with fields range from 1 × 1 cm to less than 10 × 12 cm. Beam parameters required by the Radionics treatment planning system (XPlan version 2) for evaluating the dose include tissue maximum ratio (TMR), scatter factors (SF), off-axis ratios (OAR), output factors, penumbra function (P) and transmission factors (TF) are performed in this work. Beam data are acquired with a small stereotactic diode, standard ion chambers and radiographic films. Measured profiles of dose distribution are compared to those calculated by the software and absolute dosimetry is performed.
Keywords: dosimetry, stereotactic radiosurgery, miniature multileaf collimator, radiation measurement
Journal: Journal of X-Ray Science and Technology, vol. 11, no. 1, pp. 21-31, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl