Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mintzer, J.P. | Parvez, B. | Chelala, M. | Alpan, G. | LaGamma, E.F.
Affiliations: Department of Pediatrics, Division of Neonatal-Perinatal Medicine, Stony Brook Children's Hospital, Stony Brook, NY, USA | Department of Pediatrics, Division of Newborn Medicine, The Regional Neonatal Intensive Care Unit, Maria Fareri Children's Hospital at Westchester Medical Center, Valhalla, NY, USA
Note: [] Corresponding author: Dr. Jonathan P. Mintzer, Stony Brook Children's Hospital, Division of Neonatal-Perinatal Medicine, HSC T11, Rm. 060, Stony Brook, NY 11794-8111, USA. Tel.: +1 631 444 7653; Fax: +1 631 444 8968; E-mail: jonathan.mintzer@stonybrookmedicine.edu
Abstract: OBJECTIVE: In extremely premature neonates, data concerning the normal baseline variability of near-infrared spectroscopy (NIRS)-derived regional oxygen saturation (rSO2) are lacking. We sought to determine: 1) the quiescent variability of cerebral, renal, and splanchnic rSO2 in clinically stable, undisturbed very low birth weight neonates and 2) the effects of different data averaging epochs on site-specific variability. STUDY DESIGN: In this prospective, observational study, neonates between 500 and 1250 g underwent seven days of continuous, real-time cerebral, renal, and splanchnic NIRS monitoring starting within the first seventy-two postnatal hours. Demographic, cardiopulmonary, bedside care, and rSO2 data were collected. rSO2 variability was analyzed utilizing data from quiescent periods identified using pre-specified stability criteria. Between- and within-monitoring site comparisons of data averaging methods were made utilizing ANOVA. RESULT: Twenty-four subjects (GA 27 ± 0.3 wk, birth weight 988 ± 34 g; mean ± SEM) were monitored. Coefficients of variation (CoVar = SD/mean) were calculated for each monitoring site using varied data averaging epochs. CoVar was lowest for cerebral, intermediate for renal, and highest for splanchnic rSO2 (P < 0.01). For renal and splanchnic sites, shorter epochs (5- and 15-min) resulted in significantly smaller CoVars [P < 0.01 and P < 0.05, respectively]. Splanchnic variability was highly dependent on epoch length, ranging from 16% over 5 min to 23% over 60 min. CONCLUSION: 1) rSO2 variability differs significantly between monitoring sites and 2) shorter data sampling epochs decrease rSO2 variability. These observations may assist clinicians in operationally defining minimally significant departures to enable medical decision making utilizing this monitoring technique.
Keywords: Near-infrared spectroscopy (NIRS), monitoring, noninvasive, neonate, oxygenation, regional tissue oxygenation, oxygen delivery
DOI: 10.3233/NPM-14814035
Journal: Journal of Neonatal-Perinatal Medicine, vol. 7, no. 3, pp. 199-206, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl