Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Satar, M.a; * | Erol, A.H.b | Özdemir, M.a | Özbarlas, N.c | Atmış, A.c | Özlü, F.a | Büyükkurt, S.d
Affiliations: [a] Department of Pediatrics, Division of Neonatology, Faculty of Medicine, Çukurova University, Adana, Turkey | [b] Department of Pediatrics, Faculty of Medicine Çukurova University, Adana, Turkey | [c] Department of Pediatrics, Division of Pediatric Cardiology, Faculty of Medicine, Çukurova University, Adana, Turkey | [d] Department of Obstetrics and Gynecology, Faculty of Medicine, Çukurova University, Adana, Turkey
Correspondence: [*] Address for correspondences: Prof. Dr. Mehmet Satar, Address: Gazipaşa Bulvarı No 1, Dönmez Apt 2/4 Seyhan-Adana/Turkey. Tel.: +90 322 4584498; E-mail: msatar@cu.edu.tr.
Abstract: BACKGROUND: Delayed cord clamping is the standard of care for both term and preterm infants worldwide. The aim of this study was to evaluate the effect of 60-second or 180-second delayed cord clamping during labor on cerebral oxygenation and cardiac function. METHODS: Healthy newborns were divided into two groups: a 60-second delay in cord clamping (60-s DCC) and a 180-second delay in cord clamping (180-s DCC) at birth. Pulse oximetry and cerebral near-infrared spectroscopy (cNIRS) probes were placed during postnatal care. A total of 84 healthy newborns were included in this study. Preductal oxygen saturation (SpO2), heart rate, and cNIRS values were recorded at 5 and 10 minutes after delivery. The cardiac function of the infants was assessed by echocardiography at 3–7 days postnatally. RESULTS: There was no significant difference between the groups in SpO2 and cNIRS values at 5 and 10 min. While there was no significant difference in the number of neonates with targeted SpO2 at the 5th and 10th min and targeted cNIRS values at the 10th min, there was a significant difference in the number of neonates with target cNIRS values at the 5th min between groups (p < 0.001). Echocardiographic findings showed that pulmonary flow velocity was increased in the 180-s DCC group; the difference was statistically significant (p = 0.04). CONCLUSION: Our results showed that the number of infants with normal cNIRS values regarding cerebral oxygenation was higher in the 180-s DCC group. The pulmonary flow velocity was significantly increased in the 180-s DCC group in terms of echocardiographic findings.
Keywords: Cerebral NIRS, cord clamping time, echocardiography, neonates
DOI: 10.3233/NPM-230223
Journal: Journal of Neonatal-Perinatal Medicine, vol. 17, no. 4, pp. 535-542, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl