Article type: Research Article
Authors: Reiterer, Friedrich*; | Auinger, Julia | Urlesberger, Bernd
Affiliations: Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, Graz, Austria
Correspondence: [*] Address for correspondence: Friedrich Reiterer, MD, Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz Auenbruggerplatz 38/1, 8036 Graz – Austria. Tel.: +43/0316 385 84558; Fax: +43/0316 385 12678; E-mail: friedrich.reiterer@medunigraz.at.
Abstract: BACKGROUND:Non-invasive, radiation free bedside monitoring methods have gained increased popularity in the respiratory field. The aim of our study was to report the experience with electrical impedance segmentography (EIS), a rather new technique, which allows continuous visual and quantitative monitoring of regional lung ventilation. METHODS:Prospective, pilot trial in spontaneously breathing, healthy, non-sedated term neonates between 24 and 72 hours post-delivery using a commercially available EIS-device. Systematic review of the literature. RESULTS:A total of 12 neonates were eligible for complete data analysis in our study. EIS was found to be a safe and easy to perform method. The median duration of the study time was 25 minutes (16–40). Individual total and regional impedance values, given in arbitrary units and it's percentage of distribution in the upper and lower right and left lung segments (UR, UL, LR, LL), were variable (median total impedance 207 arbitrary units (AU), UR% 17, LR 27%,UL 28%, LL 23%). A number of influencing factors such as body movements, sucking, jawing, and electrode issues have to be considered for correct data interpretation. The literature search revealed two small experimental studies in neonatal piglets and two human studies (one study in preschool children with bronchopulmonary dysplasia and one case report in a neonate with respiratory distress). CONCLUSIONS:EIS is an innovative technique and a potentially useful tool in studying regional lung ventilation in research and clinical care.
Keywords: Electrical impedance segmentography, electrical impedance tomography, neonates, regional lung ventilation, review
DOI: 10.3233/NPM-190347
Journal: Journal of Neonatal-Perinatal Medicine, vol. 13, no. 4, pp. 489-494, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl