Abstract: OBJECTIVE: To assess the association between delivery room (DR) continuous positive airway pressure (CPAP) and pneumothorax (PT) in term newborns. METHODS: Two studies performed in community hospitals used data extracted from computerized records of term newborns. Infants receiving positive pressure ventilation in the DR were excluded. Tabulated data included receipt of DR CPAP, PT on the day of birth, and gestational age (GA). In a case-control study from 2001–2013, infants with PT were compared to controls without PT but with respiratory distress or hypoxia persisting from birth for receipt of DR CPAP. In a cohort study from 2014–2016, infants receiving and not receiving DR CPAP were compared for the incidence of PT. RESULTS: In the case-control study, data were obtained for 169 cases and 850 controls. Compared to controls, PT infants were more likely to have received DR CPAP (16.8% vs. 40.2%, respectively, P < 0.001). Logistic regression revealed DR CPAP (Adjusted Odds Ratio [AOR] = 3.30, 95% confidence interval [CI] = 2.31, 4.72, P < 0.001) and GA (AOR = 1.21, 95% CI = 1.05, 1.39, P = 0.009) to be independent predictors of early PT. In the cohort study, PT was observed in 0.1% of 9255 control infants not receiving DR CPAP and 4.8% of 228 infants receiving DR CPAP (P < 0.001). In logistic regression analyses, DR CPAP significantly predicted PT (OR = 59.59, 95% CI = 23.34, 147.12, P < 0.001) and remained a significant predictor of PT after controlling for gestational age. CONCLUSION: Respiratory conditions treated with CPAP in delivery rooms are associated with increased risk of PT. A cause-and-effect relationship between CPAP and PT cannot be claimed in this study. Further research is needed to better understand this relationship.
Keywords: CPAP, resuscitation, air leak, pneumothorax
DOI: 10.3233/NPM-171694
Journal: Journal of Neonatal-Perinatal Medicine, vol. 10, no. 2, pp. 157-161, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl