Article type: Research Article
Authors: Zeng, Xingqia | Zou, Yanga | Zhou, Zhixianga; b; * | Yu, Yanjianga | Yu, Kuna | Peng, Hongboa | Zhang, Liwenc
Affiliations: [a] State Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing, China | [b] School of Civil Engineering, Chongqing Jiaotong University, Chongqing, China | [c] College of Civil and Transportation Engineering, Shenzhen University, Shenzhen, Guangdong, China | [d] China Design Group Co., Ltd., Nanjing, Jiangsu, China
Correspondence: [*] Corresponding author: Zhixiang Zhou, College of Civil and Transportation Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China. E-mail: zhixiangzhou@szu.edu.cn.
Abstract: In this study, a test beam model of negative moment region was designed to study its deflection characteristics under over-limit static load and variable amplitude cyclic load scenarios. (1) According to the deflection test results of the test beam under over-limit static load, the load-deflection curve under static load before and after 10000 times of over-limit fatigue load tended to sharply increase in the first place and then slow down afterwards. At the ultimate load, the maximum deflection value of the two was 8.625 mm and 8.76 mm, respectively. The maximum deflection value after 10000 times of over-limit fatigue load increased by 1.57% compared with that before. (2) The deflection test results of the test beam under variable amplitude cyclic load showed that both the total deflection and the residual deflection percentage increased firstly and decreased with the increasing fatigue load times. The total deflection ranged from 4.07–4.3 mm, and the residual deflection percentage was 0.1–1.65%; The residual deflection percentage reached a maximum of 1.65% when the fatigue load times reached 2 million. (3) The deflection test results of the test beam under over-limit variable amplitude fatigue load showed that the maximum residual deflection reached 0.08 mm (maximum residual deflection percentage 1.75%), 0.11 mm (maximum residual deflection percentage 2.30%), 0.16 mm (maximum residual deflection percentage 2.65%) after 1.5, 2 and 3 times over-limit variable amplitude fatigue load was imposed respectively. The maximum deflection did not fluctuate obviously, indicating that the test beam was had sound working performance. (4) In this study, the shear stiffness and fatigue load times were fully considered, the mean value of the ratio of the deformation value to the measured value of the test beam was 0.89, and the standard deviation was 4.86%. When the fatigue load times exceeded 2.8 million, the ratio of the calculated value to the measured value was less than 0.85. In conclusion, the model had its own limitations.
Keywords: Steel truss-concrete, test beam, deflection characteristics, fatigue load, the maximum deflection
DOI: 10.3233/JCM-226164
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 22, no. 5, pp. 1533-1544, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl