Authors: Tang, Xiaojun | Huang, Yijiang | He, Shaoqi | Tang, Chengxuan | Peng, Maoxiu | Dai, Minghai | Chen, Wenliang*
Affiliations: Department of Orthopaedics, The Third Affiliated Hospital of Wenzhou Medical College, Wenzhou, Zhejiang 325200, China
Correspondence: [*] Correspnding author: Wenliang Chen, Wansong Road 108, Ruian City, Zhejiang Province, The Third Affiliated Hospital of Wenzhou Medical College, Wehzhou, Zhejiang, China. E-mail: wenliang.chen@aol.com.
Abstract: BACKGROUND: It is important to evaluate clinical efficacy and safety of posterior internal fixation using pedicle screw system. OBJECTIVES: To investigate clinical characteristics of patients diagnosed with fracture-dislocation of the thoracic spine with or without minimal spinal cord. METHODS: Twenty-eight patients with fracture-dislocation of thoracic spine with or without minimal spinal cord injury were retrospectively analyzed. All patients received posterior reduction and internal fixation using pedicle screw system. RESULTS: The mean follow-up duration was 11.4 months. Among 28 patients, 24 cases were complicated with bilateral pedicle or laminal fracture. Preoperatively, the percentage of vertebral displacement was (32.1 ± 20.6)%, significantly declined to (7.5 ± 6.0)% (t= 4.575, P= 0.001) and maintained at (7.9 ± 6.3)% at the final follow-up. Preoperative local kyphosis angle was measured as (16.2 ± 11.3)∘, restored to (15.4 ± 5.9)∘ postoperatively and (15.8 ± 5.4)∘ during the final follow-up. No statistical significance was observed at three time points (all P> 0.05). The remaining 25 patients were evaluated with normal and complete neurological function. No severe complications were observed intra- and postoperatively. CONCLUSIONS: Posterior internal fixation using pedicle screw is an efficacious and safe therapy which achieves proper reduction and preserves spinal cord function.
Keywords: Clinical characteristics, fracture dislocation, pedicle screw, spinal cord injury, thoracic spine
DOI: 10.3233/BMR-181410
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 33, no. 3, pp. 437-442, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl