Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ng, How Hinga | Lin, Wen-Yenb; d | Lei, Kin Fongc; d | Cheng, Chih-Hsiua; d | Jeng, Shiau-Chiana; f | Lin, Yang-Huaa; d; e; *
Affiliations: [a] Department of Physical Therapy and Graduate Institute of Rehabilitation Science, College of Medicine, Chang Gung University, Taoyuan, Taiwan | [b] Department of Electrical Engineering, College of Engineering, Chang Gung University, Taoyuan, Taiwan | [c] Department of Mechanical Engineering and Graduate Institute of Medical Mechatronics, College of Engineering, Chang Gung University, Taoyuan, Taiwan | [d] Healthy Aging Research Center, Chang Gung University, Taoyuan, Taiwan | [e] Division of Physical Therapy, Department of Physical Medicine and Rehabilitation, Chiayi Chang Gung Memorial Hosipital, Chiayi, Puzi, Taiwan | [f] National Keelung Special Education School, Keelung, Taiwan
Correspondence: [*] Corresponding author: Yang-Hua Lin, Department of Physical Therapy, College of Medical, Chang Gung University, 259, Wen-Hwa 1st Rd, Gweishan, Taoyuan 333, Taiwan. Tel.: +886 3 2118800 5438; Fax: +886 3 2118700; E-mail: linyh@mail.cgu.edu.tw.
Abstract: BACKGROUND: Mechanomyography (MMG) has been used to investigate mechanical characteristics of muscle contraction in clinical and experimental settings. OBJECTIVE: The aim of this study was to determine the test-retest reliability of mechanomyographic amplitude (MMGRMS) measurements as a tool for measuring the maximal voluntary isometric contractions (MVICs) of trunk muscles in healthy participants. METHODS: There were ten young adults participating in this study. Accelerometers were used to detect surface MMG signals from three trials of 5-s MVICs of the rectus abdominis, external obliques, erector spinae, and multifidus in the vertical, transverse, and longitudinal directions. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimum detectable change were calculated. RESULTS: Good to excellent test-retest reliability of mechanomyographic amplitude (MMGRMS) measurements was achieved for all MVICs of trunk muscles in healthy participants, as indicated by ICCs ranging from 0.99 to 0.64 for MMGRMS of the trunk muscles during MVIC. CONCLUSIONS: This study demonstrates that MMG is a reliable measurement to detect the activation amplitudes of trunk muscles during MVIC.
Keywords: Test-retest reliability, mechanomyography, trunk muscle, maximal voluntary isometric contraction
DOI: 10.3233/BMR-159364
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 30, no. 5, pp. 979-985, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl