Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bedekar, Nilimaa; * | Suryawanshi, Mayuria | Rairikar, Savitaa | Sancheti, Paragb | Shyam, Ashokb
Affiliations: [a] Sancheti Institute College of Physiotherapy, Pune, India | [b] Consultant Orthopaedics, Sancheti Institute for Orthopaedics and Rehabilitation, Pune, India
Correspondence: [*] Corresponding author: Nilima Bedekar, Sancheti Institute College of Physiotherapy, Shivajinagar, Pune 411005, India. Tel.: +91 2025539393; Fax: +91 2025539494; E-mail: nilimabedekar@yahoo.com
Abstract: Background:Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). Objectives:To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. Method:iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. Results:Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. Conclusion:Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
Keywords: Reliability, mobile device, iTune goniometer, range of motion
DOI: 10.3233/BMR-130431
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 27, no. 2, pp. 161-166, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl