Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Willemse, Eline A.J.a; b; * | Durieux-Lu, Sisia | van der Flier, Wiesje M.b; c | Pijnenburg, Yolande A.L.b | de Jonge, Roberta | Teunissen, Charlotte E.a
Affiliations: [a] Clinical Chemistry, Neuroscience Campus Amsterdam, VU University Medical Center Amsterdam, The Netherlands | [b] Neurology and Alzheimer Center, Neuroscience Campus Amsterdam, VU University Medical Center Amsterdam, The Netherlands | [c] Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, The Netherlands
Correspondence: [*] Correspondence to: EAJ Willemse, Neurochemistry Laboratory, room PK1BR016, Department of Clinical Chemistry and Alzheimer Center, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands. Tel.: +31 20 44 43868; E-mail: e.willemse@vumc.nl.
Abstract: Progranulin (PGRN) levels in blood and cerebrospinal fluid (CSF) are increasingly studied as potential markers for neurodegenerative disorders. We aimed to 1) characterize two commercially available PGRN ELISAs on several assay validation parameters, 2) assess the stability of PGRN in serum and CSF under pre-analytical conditions, and 3) compare stability in the two assays. Intra- and inter-assay variation, inter-lot variation, linearity, lower limit of detection, and kit correlations were assessed for the Adipogen and R&D PGRN ELISA kits. Blood and serum samples were experimentally exposed to ≤9 freeze/thaw cycles, delayed processing for ≤24 h at room temperature and 4°C, and to temperature stability tests for ≤3 weeks at –20°C, 4°C, room temperature, and 37°C. Both commercial PGRN ELISA kits showed acceptable ranges for intra- and inter-assay variation, where the R&D kit performed more accurate than the Adipogen kit, especially for inter-assay variation (intra-assay serum: 6.7 and 8.3%, respectively; inter-assay serum: 9.2 and 21.0%; intra-assay CSF: 3.6 and 12.0%; inter-assay CSF: 16.0 and 44.5%). Absolute serum PGRN concentrations were 1.9-fold higher in Adipogen than R&D (p < 0.001) and strongly correlated between both kits (ρ= 0.86, p < 0.0001) and CSF PGRN levels were on the borderline of detection in both kits. PGRN was typically stable under all pre-analytical conditions addressed, although two weeks at 37°C resulted in decreased PGRN concentrations in CSF, only when using the Adipogen kit. These results support further examination of PGRN as a potential marker in neurodegenerative diseases, since PGRN is stable in serum and CSF and can be measured using ELISA kits from several providers.
Keywords: Cerebrospinal fluid, human progranulin protein, ELISA, method comparison, pre-analytical variation, protein stability, serum
DOI: 10.3233/JAD-160061
Journal: Journal of Alzheimer's Disease, vol. 53, no. 1, pp. 107-116, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl