Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Buelvas, Homer; * | Benjumea, José M. | Chio, Gustavo
Affiliations: School of Civil Engineering, Universidad Industrial de Santander, Bucaramanga, Colombia
Correspondence: [*] Corresponding author. José Benjumea. School of Civil Engineering, Universidad Industrial de Santander, Carrera 27 Calle 9, Bucaramanga, Colombia, 680002. Tel.: +57 7634400 Ext. 2930. E-mail: josbenro@uis.edu.co.
Abstract: The rupture of a cable in cable-supported bridges is an accidental condition that should be considered during the design phase due the impact that this situation could have on the structural safety of the bridge and users. For that reason, design guidelines suggest carrying out a pseudo-static analysis where the failing cable is replaced by a load of the same magnitude as the pre-rupture tension but applied in the opposite direction and multiplied by a dynamic amplification factor (DAF) between 1.5 and 2.0. Previous studies in cable-stayed bridges have shown that the pseudo-static approach may not be suitable. Due to the wide use of extradosed bridges in infrastructure projects around the world, a computational analysis was performed in this investigation to estimate the dynamic amplification factors of extradosed bridge girders and cables when sudden failure of an extradosed cable occurs. The main goal of the study is to determine whether the pseudo-static approach suggested in the guidelines is acceptable. Linear response history analyses were performed by using computational models of extradosed bridges in which the girder stiffness and the suspension (lateral or central) and cable layout (fan or harp) of the cables were modified. From the analysis, the DAFs were calculated and compared to those recommended in the design guidelines. The calculated DAFs for the axial forces and bending moment in the girder of the bridges and for the axial forces in the extradosed cables were smaller than 2.0. However, in some cases the DAF for shear forces were higher than 2.0, especially when the girder stiffness was relatively low. The results indicate that the recommendations of the design guidelines are adequate for extradosed bridges, which is a result of the relatively high stiffness of the girder and low inclination of extradosed cables. Despite this, response history analyses like the one performed in this study are recommended to assess the response of the bridge under cable breakage.
Keywords: Extradosed bridge, dynamic amplification factor (DAF), cable failure, rupture, rigid deck, flexible deck
DOI: 10.3233/BRS-210189
Journal: Bridge Structures, vol. 17, no. 3-4, pp. 101-110, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl