Authors: Azadi, Nargesa | Afshari, Davooda; * | Rami, Mohammadb | Nourollahi-Darabad, Maryama | Shirali, Gholamabbasa | Angali, Kambiz Ahmadic
Affiliations: [a] Department of Occupational Health Engineering, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran | [b] Department of Sports Physiology, Faculty of Sport Sciences, Shahid Chamran University of Ahvaz, Ahvaz, Iran | [c] Environmental Technology Research Center, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
Correspondence: [*] Address for correspondence: Davood Afshari, Department of Occupational Health Engineering, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. E-mails: davodafi@yahoo.com, Afshari@ajums.ac.ir.
Abstract: BACKGROUND:Assessment of maximal oxygen consumption is important in both general community and occupational settings. Validity and reliability tests are needed to indicate the functionality of the cardiopulmonary system. OBJECTIVE:This study aimed to establish a maximal oxygen consumption (VO2max) prediction model using anthropometric and demographic variables for young adults in Iran. METHODS:This cross-sectional study was conducted on 64 healthy young men aged 19–29 years. Oxygen consumption was measured directly and the prediction models to estimate VO2max were determined by multiple linear regression. The accuracy of the prediction models was considered using regression coefficient (R), coefficient of determination (R2), and standard error of estimate (SEE). RESULTS:The average VO2max was 44.02±4.31 ml/kg/min. Significant correlations were found between the measured VO2max and the anthropometric and demographic variables (r = 0.16–0.86, P < 0.05). Three significant regression models with acceptable accuracy were developed (R2 = 0.67–0.71, SEE = 3.19–3.21). CONCLUSION:The predictive models consisted of 3–5 variables as significant predictors of VO2max and had acceptable accuracy for Iranian young adults. The proposed models are a simple and valid tool that can be used to estimate the VO2max in the field and in laboratory settings.
Keywords: VO2max, cardiopulmonary, maximal aerobic capacity, physical workload
DOI: 10.3233/WOR-220435
Journal: Work, vol. 76, no. 3, pp. 1233-1238, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl