Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Maleki-Ghahfarokhi, Azama | Azghani, Mahmood-Rezab | Asghari-Jafarabadi, Mohammadc; d | Dianat, Imane; *
Affiliations: [a] Student Research Committee, Department of Occupational Health, Faculty of Health, Tabriz University of Medical Sciences, Tabriz, Iran | [b] Department of Biomechanics, Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran | [c] Center for the Development of Interdisciplinary Research in Islamic Sciences and Health Sciences, Tabriz University of Medical Sciences, Tabriz, Iran | [d] Department of Statistics and Epidemiology, Faculty of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran | [e] Department of Occupational Health, Faculty of Health, Tabriz University of Medical Sciences, Tabriz, Iran
Correspondence: [*] Address for correspondence: Iman Dianat, Department of Occupational Health, Faculty of Health, Tabriz University of Medical Sciences, Tabriz, Iran. E-mail: dianati@tbzmed.ac.ir.
Abstract: BACKGROUND:Using both hands is regularly needed for force/torque exertions in many activities, especially when using hand tools. OBJECTIVE:To investigate the effects of tool grip span, workpiece orientation, moving direction, and working height on two-handed wrist U/R deviation torque strength, usability, comfort, and discomfort while using locking pliers. METHODS:Participants (n = 22) took part in an experimental study which evaluated the effects of tool grip span (4.5–6.5 cm), workpiece orientation (transverse/sagittal), moving direction (clockwise (CW)/counterclockwise (CCW)), and working height (shoulder/elbow/knuckle) on two-handed wrist U/R deviation torque, (dis)comfort, and usability while using locking pliers. RESULTS:The results showed no significant effect of tool grip span on wrist U/R deviation torque strength, but the locking pliers with 4.5 cm handle grip span led to more comfort and better usability. The two-handed wrist U/R deviation torque strengths were significantly higher in sagittal plane than in transverse plane, and in CW direction than in CCW direction. The highest values of two-handed wrist U/R deviation torque strength in sagittal and transverse planes were exerted in knuckle and elbow heights, respectively. CONCLUSION:The findings can be used to develop guidelines and recommendations with regard to daily and occupational activities which require the use of both hands for force exertion with manual hand tools.
Keywords: Hand tools, locking pliers, two-handed torque, usability, wrist torque
DOI: 10.3233/WOR-211397
Journal: Work, vol. 74, no. 4, pp. 1539-1549, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl