Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Karpman, Jessea; * | Gross, Douglas P.b | Manns, Patriciab | Tomkins-Lane, Christyc
Affiliations: [a] Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, CanadaCanada | [b] Department of Physical Therapy, University of Alberta, Edmonton, Canada | [c] Department of Health and Physical Education, Mount Royal University, Calgary, Canada
Correspondence: [*] Address for correspondence: Jesse Karpman, 3-48 Corbett Hall, University of Alberta Edmonton, Alberta, Canada T6G 2G4. Tel.: +1 780 492 2499; Fax: +1 780 492 1626; E-mail: jkarpman@ualberta.ca.
Abstract: BACKGROUND:The use of wearable accelerometers in conjunction with Functional Capacity Evaluation (FCE) may provide additional useful information about maximum performance in workers and enhance the validity of functional testing. However, little research has been conducted to compare accelerometer output with performance during FCE. OBJECTIVE:The objectives of this study were to: (1) Determine the magnitude and direction of correlation between participant performance on five FCE tasks and scores from Actigraph activity monitors; and (2) Compare the results of two different placements of Actigraph devices. METHOD:We used a cross-sectional design and convenience sampling to collect data from 46 healthy participants. Each participant completed 5 functional tasks selected from the WorkWell FCE protocol while wearing 2 Actigraph devices, 1 on the dominant side waist and 1 on the non-dominant wrist. The FCE tasks included 5-repetition maximum lifting (floor-to-waist, waist to crown and front carry), a sustained overhead work endurance task, and the 6-minute walk test. Analysis included calculating Pearson regression coefficients between maximum FCE item performance and Actigraph vector magnitudes (VM) along with Intraclass Correlation Coefficients (ICC) to compare VM activity counts derived from the Actigraphs on the waist and wrist. RESULTS:Thirty-Nine (84.8%) participants had complete data and were included in analysis. Findings indicate Actigraph VM data from the device worn on the waist correlated positively with maximum lift performance (r = 0.39–0.64, p < 0.001 to 0.08) and 6-minute walk distance (r = 0.66, p < 0.001). Actigraph data from wrist placement were not significantly correlated with FCE performance on any of the functional tasks, except when comparing average VM data and waist to crown lift (r = 0.44, p < 0.001). There was no significant correlation in either Actigraph placement for VM and overhead work time. ICCs between the two Actigraph placements ranged from poor to acceptable agreement (ICC = 0.24–0.70, p < 0.001 to 0.19). CONCLUSIONS:Actigraph device output correlated moderately with maximum performance on FCE lift and ambulation tests. Waist placement appears more suitable than wrist during performance-based tests.
Keywords: Accelerometry, disability evaluation, motor activity, return to work, exercise test
DOI: 10.3233/WOR-203164
Journal: Work, vol. 66, no. 1, pp. 201-211, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl