Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Li, Zhaoxia | Guo, Xiaohuia; * | Shi, Weia | He, Rongxiab | Zhong, Huac
Affiliations: [a] Department of Obstetrical, Shenzhen People’s Hospital, Shenzhen, China | [b] Department of Obstetrical, Lanzhou University Second Hospital, Lanzhou, China | [c] Department of Obstetrical, Affiliated Hospital of Southwest Medical University, Luzhou, China
Correspondence: [*] Corresponding author: Xiaohui Guo, Department of Obstetrical, Shenzhen People’s Hospital, No. 1017 of Dongmen North Road, Luohu District, Shenzhen 518020, China. Tel.: +86 18676796981; E-mail: xiaohuiguo263@163.com.
Abstract: BACKGROUND: Electronic foetal monitoring (EFM), a method to monitor foetal intrauterine conditions and foetal reserve capacity, is the most extensively used intrauterine monitoring technology in obstetrics. OBJECTIVE: This study aims to compare the Thoth wearable foetal electrocardiogram (foetal ECG [FECG]) monitoring system with a traditional Doppler foetal heart monitoring system before labour to investigate their respective values in clinical application. METHODS: A total of 393 pregnant women admitted to our hospital between 2020 and 2022 participated in this study. They were recruited using the convenience sampling method. We employed a paired design to assess the confusion rate, trend overlap, and foetal heart rate/ECG monitoring consistency, whereas a completely randomised design was used to measure pregnancy outcome indicators. The participants were divided into two groups using a random number table: the Thoth group (n= 196) and the traditional Doppler group (n= 197). Each group was monitored using the corresponding system. RESULTS: The Thoth monitor demonstrated a lower confusion rate compared with the traditional Doppler monitor (0.25% vs 2.04%; χ2= 5.508, P= 0.019). The trend overlap in foetal heart rates was consistently 100%, with 91.2% of readings showing a consistency rate of ⩾ 95%. Additionally, the Thoth monitor recorded a higher cumulative interruption time in the foetal heart rate curve (12.13 ± 2.22 vs 21.02 ± 2.34; t= 18.471, P< 0.001) and more abnormal ECGs (21.21 ± 4.32 vs 18.21 ± 2.91; t= 7.582, P< 0.001) than the traditional Doppler system. CONCLUSION: The Thoth wearable FECG monitor offers several advantages over the traditional Doppler foetal heart monitoring system. These include a reduced confusion rate, more accurate data collection, a lower rate of clinical misjudgement, reduced workload for medical staff, and enhanced comfort during vaginal delivery. The rates of emergency caesarean sections and neonatal asphyxia in the Thoth group were marginally lower than those in the Doppler group, which may be attributed to issues such as ECG disconnection or interference from the maternal heart rate.
Keywords: Foetal heart monitoring, foetal ECG monitor, Thoth wearable device, Doppler device, heart rates
DOI: 10.3233/THC-231752
Journal: Technology and Health Care, vol. 32, no. 6, pp. 4031-4040, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl