Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: He, Hui* | Yan, Shuai | Chen, Dan-Dan | Guo, Cong | Xi, Zeng-Hui
Affiliations: Department of Ultrasonic Diagnosis, The 983th Hospital of Joint Logistic Support Force of PLA, Tianjin, China
Correspondence: [*] Corresponding author: Hui He, Department of Ultrasonic Diagnosis, The 983th Hospital of Joint Logistic Support Force of PLA, No. 60 Huang Wei Road, Hebei District, Tianjin 300142, China. Tel.: +86 13302003788; Fax: +86 22 84683523; E-mail: hehui569869@outlook.com.
Abstract: BACKGROUND: Secondary hyperparathyroidism (SHPT) is one of the common complications of end-stage renal disease-uremia, and is mainly manifested as parathyroid hyperplasia and abnormal secretion of parathyroid hormone (PTH). OBJECTIVE: To investigate the value and advantages of contrast-enhanced ultrasound (CEUS) in evaluating the survival of autografts after parathyroidectomy + parathyroid autotransplantation. METHODS: In this study, 125 patients with renal failure due to polycystic kidney disease, chronic nephritis, diabetic nephropathy, lupus nephritis, and atherosclerotic nephropathy were enrolled as the participants and each of them had 4 secondary hyperactive parathyroid glands and underwent parathyroid autotransplantation. One parathyroid gland was taken from each patient and equally divided into 4 parts and placed in the subcutaneous fat of one forearm for transplantation. CEUS was performed 14 days after the transplantation to observe the micro blood supply of the graft and assess the survival and secretory function of the transplanted parathyroid. The grafts were divided into the partial survival group and the total survival group based on the enhancement characteristics. The survival of the grafts was determined by comparing the parathyroid hormone level in bilateral elbow cephalic veins 1 month after surgery. RESULTS: Among the 125 patients, 112 had linear or punctate enhancement of 2–4 parathyroid glands 14 days after surgery, and 13 patients had linear or punctate enhancement of 0–1 parathyroid gland. There were statistically significant differences in the perfusion pattern, enhancement uniformity, and parathyroid hormone levels in the cephalic veins at the elbow on both the graft and non-graft sides among all groups (P< 0.05). CONCLUSION: Compared to the detection of the difference in the parathyroid hormone level in the cephalic vein of bilateral elbows 1 month after surgery, CEUS can reflect the parathyroid survival after transplantation more quickly and accurately 2 weeks later, and provide a more rapid and agile non-invasive clinical diagnosis method.
Keywords: Contrast-enhanced ultrasound (CEUS), parathyroid autotransplantation, secondary hyperparathyroidism, survival
DOI: 10.3233/THC-231191
Journal: Technology and Health Care, vol. 32, no. 5, pp. 2941-2949, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl