Article type: Research Article
Authors: Vulović, Aleksandraa; b | Warchomicka, Fernando Gustavoc | Pixner, Florianc | Filipović, Nenada; b; *
Affiliations: [a] Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia | [b] Bioengineering Research and Development Center, Kragujevac, Serbia | [c] Institute of Materials Science, Joining and Forming, Graz University of Technology, Graz, Austria
Correspondence: [*] Corresponding author: Nenad Filipović, Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia. E-mail: fica@kg.ac.rs.
Abstract: BACKGROUND: In order to ensure the proper function of the cementless hip implant, the connection between the femoral bone and the implant has to be as strong as possible. According to experimental studies, implants with a rough surface reduce micro-movements between femoral bone and implant, which helps form a stronger connection between them. OBJECTIVE: The goal of this study was to analyze how half-cylinder surface topographies of different diameter values affect shear stress values and their distribution on the surface of the hip implant and trabecular femoral bone. METHODS: Nine models with different half-cylinder diameter values (200 μm, 400 μm, and 500 μm) and distances between half-cylinders were created for the analysis using the finite element method. Each model consisted of three layers: implant, trabecular, and cortical femoral bone. RESULTS: For all three diameter values, the highest shear stress value, for the implant layer, was located after the first half-cylinder on the side where force was defined. For the trabecular bone, the first half-cylinder was under lower amounts of shear stress. CONCLUSION: If we only consider shear stress values, we can say that models with 400 μm and 500 μm diameter values are a better choice than models with 100 μm diameter values.
Keywords: Finite element analysis, hip implant, shear stress, surface topography
DOI: 10.3233/THC-230692
Journal: Technology and Health Care, vol. 32, no. 2, pp. 1123-1133, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl