Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jia, Limina | Zhang, Chenguangb | Fu, Xinc | Chen, Caihuaa | Zheng, Hongkuia | Yang, Caifanga; *
Affiliations: [a] Department of Cardiothoracic Surgery, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang, China | [b] Department of Urology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang, China | [c] Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang, China
Correspondence: [*] Corresponding author: Caifang Yang, Department of Cardiothoracic Surgery, Taizhou Hospital of Zhejiang Province affiliated to Wenzhou Medical University, No. 150 Ximen Street, Linhai, Taizhou, Zhejiang 317000, China. Tel.: +86 13867656416; E-mail: caifang9821@163.com.
Abstract: BACKGROUND: The use of indwelling closed thoracic drainage tubes in the wedge resection of the lungs is of great significance to postoperative recovery. However, there are potential risks. OBJECTIVE: To explore the design feasibility and application effect of triple-buffer-system-fixed small-diameter (18 F) thoracic closed drainage tubes following lung wedge resection. METHODS: A total of 136 patients with indwelling thoracic drainage tubes following pulmonary wedge resection were recruited, with 70 patients allocated to the control group and 66 to the experimental group. The drainage tube in the experimental group was fixed with the triple-buffer system, while that in the control group was fixed using the conventional lifting platform method. The incidence of unplanned extubation, the indwelling time of the drainage tube and the time and material costs, as well as information regarding any subcutaneous emphysema and skin tension blisters, were recorded following the operation. The pain and degree of comfort were assessed using a chi-square test and a rank sum t-test to compare the differences between the two groups. RESULTS: There were no statistically significant differences in terms of age, gender and sweating between the two groups. Compared with the control group, the unplanned extubation rate of the experimental group was lower (χ2= 8.513; P= 0.004), the indwelling time of the drainage tube was shorter (t= 2.108; P= 0.037), the cumulative material cost was lower (t= 3.778; P< 0.001), the time cost was also lower (Z= 2.717; P= 0.008), the degree of comfort was higher (Z= 2.752; P= 0.006), and the degree of pain was lower (Z= 4.019; P< 0.001). The incidence of subcutaneous emphysema was significantly lower in the experimental group than in the control group (χ2= 8.513; P= 0.004). CONCLUSION: The use of the triple-buffer system to fix small-diameter (18 F) thoracic closed drainage tubes can reduce the unplanned extubation rate, indwelling time of the drainage tube and the incidence of adverse reactions.
Keywords: Lung wedge resection, small-diameter closed thoracic drainage tube, fixed method
DOI: 10.3233/THC-230558
Journal: Technology and Health Care, vol. 32, no. 3, pp. 1503-1513, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl